MAINTENANCE / SPECIFICATIONS

SPECIFICATIONS:

 

 

 

 

 

System operating voltage

 

120vac +/- 20% @ 50-60 Hertz

Maximum Switching amperage

 

15-amps @ 120vac

Overload protection

 

15-amp normal blow fuse

Operating temperature

 

0 - 50’ C / 32 - 122’ F

Maximum humidity

 

95% RH (Non-condensing)

Temperature control range

 

50-115’ F with a 7’ F differential, +/- 3.6’

Humidity control range

 

20 - 80% RH with a 5% differential

Adjustable timer repeatability

 

+/- .2% under fixed conditions

Timer setting accuracy

 

+/- 5%

Hydro “ON” timer

 

1 second to 40 minutes

Hydro “OFF” timer

 

1 minute to 8 hours

CO2 Inject duration timer

 

1 second to 40 minutes

CO2 Inject frequency timer

 

1 minute to 8 hours

24-hour timeclock accuracy

 

+/- 3% monthly

Dimensions

 

10” X 8” X 7”

Weight

 

Less than 6 lbs.

Relay operations

 

Minimum 100,000 electrical / 10,000,000 mechanical

MAINTENANCE:

1)Consult the troubleshooting chart for a listing of the most common problems.

2)DO NOT open the enclosure!!! There are no components that require maintenance.

3)Do not use this equipment for purposes other than what it is designed for. It will provide many years of trouble-free service when used properly.

4)In the event you cannot solve the problem, first consult the dealer who sold the unit then contact the factory for instructions on how to return it to the factory for repair.

PUBLISHED BY R & M Supply INC.

COPYRIGHT 2008 BY R & M Supply

ALL RIGHTS RESERVED.

Liability statement:

R & M Supply and their retailers and distributors are not responsible for any damage or injuries (consequential or otherwise) arising from the use of this device. The purchaser assumes all responsibility for the use and proper installation of this device.

Page 10

Image 10
Contents Do not use 2-wire adapters or cords to operate the CGC-1e WarrantyInstallation / START-UP OverviewExample Connection Diagram do not Exceed 15 Amps Total Front PanelSTART-UP Procedure HOW to START-UP the CGC-1eControls Hydroponics Timers TimersAdjustable Recycling Timers CO2 TimersSupplemental CO2 Timed CO2 Control ModeCO2 Control CO2 Control ModesPPM Part-Per-Million CO2 Control Mode PPM-1cPART-PER-MILLION CO2 Sensor PPM-1c Universal Power Module UPM-1Options Master Lighting Controller MLCsTroubleshooting Making ConnectionsMaintenance Maintenance / SpecificationsSpecifications ALL Rights Reserved