Quantum Instruments Splitter Boxes manual Fieldbus characteristics

Page 26

Characteristics

IP 67 monobloc I/O splitter boxes

 

for fieldbuses

 

AdvantysDistributed I/O, FTB splitter boxes

Environmental characteristics

 

Product certifications

 

 

 

cULus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

Operation

°C (°F)

 

0 to + 55 (+ 32... 131)

 

 

 

 

 

Storage

°C (°F)

 

- 25 to + 70 (-13...+ 158)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Degree of protection

Conforming to IEC 60529

 

 

IP 67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Altitude

 

m (ft.)

 

0 to 2000 (0 to 6562)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vibration resistance

Conforming to IEC 68-2-6,

Hz

 

For plastic housing

5 f 57.55 (constant amplitude = 1.5 mm)

 

 

test Fc

 

 

 

 

57.55 f 500 (constant acceleration = 10 gn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For metal housing

5 f 70 (constant amplitude = 1.5 mm)

 

 

 

 

 

 

 

70 f 500 (constant acceleration = 15 gn)

 

 

 

 

 

 

 

 

 

 

 

Shock resistance

Conforming to IEC 68-2-27,

 

 

For plastic housing

30 gn, for 11 ms

 

 

 

test Ea

 

 

 

 

 

 

 

 

 

 

 

 

For metal housing

50 gn, for 11 ms

 

 

 

 

 

 

 

 

 

 

 

 

Resistance to electrostatic

Conforming to IEC 61000-4-2

kV

 

Contact: ± 4

 

 

 

 

 

discharge

 

 

 

Air: ± 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance to radiated fields

Conforming to IEC 61000-4-3

V/m

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Immunity to fast transient

Conforming to IEC 61000-4-4

kV

 

Power supply: ± 2

 

 

 

 

currents

 

 

 

Signal: ± 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Surge withstand

Conforming to IEC 61000-4-5

V

 

Power supply: (symmetrical) ± 500, (asymmetrical) ± 1000

 

 

 

 

 

 

Signals: (symmetrical) ± 500, (asymmetrical) ± 1000

 

 

 

 

 

 

Ground/PE: ± 500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Immunity to conducted

Conforming to IEC 61000-4-6

Vrms

 

10

 

 

 

 

 

disturbance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistance to magnetic

Conforming to IEC 61000-4-8

A/m

 

30

 

 

 

 

 

fields, 50 Hz

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

All positions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical mounting

 

 

 

Mounting by two M4 screws for plastic housing (tightening torque 1.5 Nm / 13.3 lbf-in)

 

 

 

 

 

Mounting by two M6 screws for metal housing (tightening torque 9 Nm / 79.7 lbf-in)

 

 

 

 

 

 

 

 

 

Fieldbus characteristics

 

 

 

 

 

 

 

 

Bus type

 

CANopen

DeviceNet

 

Profibus-DP

InterBus

 

Structure

Type

EN 50325

EN 50325

 

DIN 19245

DIN 19258

 

 

 

ISO 11898

ISO 11898

 

EN 50170

EN 50254

 

 

 

 

 

 

CAN, layer 7

 

 

 

 

 

 

 

 

DeviceNet

 

 

 

 

 

 

 

 

 

 

 

 

 

Access method

Multimaster, priority

Master-Slave

Master-Slave,

Master-Slave

 

 

 

information

 

 

Multi-Master

 

 

 

 

 

 

 

 

 

 

 

 

Transmission

Binary rate

1 Mbits/s

 

500 kbits/s

 

12 Mbits/s

500 kbits/s

 

 

 

 

 

 

 

 

 

 

Medium

2 twisted, shielded

4 twisted, shielded

2 twisted, type A,

3 twisted pairs with

 

 

 

wires

 

wires

 

shielded wires

common shielding

 

 

 

 

 

 

 

 

(RS 485)

Fiber optic

 

 

 

 

 

 

 

 

 

 

 

Configuration

Maximum number of devices

127

 

 

63

 

32 without repeater

256

 

 

 

 

 

 

 

 

126 with repeaters

 

 

 

 

 

 

 

 

 

 

 

Maximum length of bus

At 1 Mbits/s:

Main line:

 

Without repeater:

Main bus link

 

 

 

- Max. tap-off length:

- 500 m (1640 ft.)

At 12 Mbits/s:

(long distance bus):

 

 

 

0.3 m (0.98 ft.)

without repeater,

- 100 m (328.1 ft.)max.

12.8 km (41,999 ft.)

 

 

 

- Max. cumulative

 

 

At 1.5 Mbits/s:

Local bus link:

 

 

 

tap-off length: 1.5 m

- 3 km (9843 ft.)with

 

 

 

(4.9 ft.)

 

repeater

 

- 200 m (656.2 ft.)max.

50 m (164 ft.)

 

 

 

At 500 kbits/s:

Tap-off:

 

At 500 kbits/s:

 

 

 

 

- Max. tap-off length:

6 m (19.7 ft.) max.

- 400 m (1312 ft.)max.

 

 

 

 

6 m (19.7 ft.)

 

 

At < 93.75 kbits/s:

 

 

 

 

- Max. cumulative

 

 

 

 

 

 

tap-off length: 30 m

 

 

- 1.2 km (3937 ft.)max.

 

 

 

 

(32.8 ft.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presentation, functions:

Description, configuration:

References:

Dimensions:

 

 

 

pages 14 - 17

pages 18 , 21, 24,

pages 28 - 30

pages 31 - 33

 

 

 

 

 

 

 

 

 

 

 

 

26

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Image 26
Contents IP 67 I/O Splitter Boxes Catalog JanuaryPage 0IP 67 I/O Splitter Boxes Housing type Type of signalType of input/output connectors Fieldbus typeModular I/O splitter boxes Advantys, FTM splitter boxes IP 67 passive splitter boxes PresentationDescription Connection characteristics Environmental characteristicsChannel characteristics Substitution tableSplitter boxes only, M12 AccessoriesReferences Separate componentsDimensions Connector connectionABE 9C124 pL pp + 8 I/O 8 I + 8 diagnostic I/O 16 I 8 I + 8 diagnostic inputs16 I/O 8 I/O+ 8 diagnostic I/O FTB 1DNpppP0 FTB 1DNpppM0 FTB 1DPpppP0 FTB 1DPpppM0 FTB 1IB FTB Selection of signal type per channelFunctions Pp16E Pp08E08S Pp12E04S Pp16C 1D p08E08C M12Actuator short-circuit DiagnosticsDiagnostics per channel Sensor short-circuit Actuator warningCANopen and DeviceNet bus extensions CANopen bus presentationDeviceNet bus presentation DeviceNet bus configuration ConfigurationCANopen bus configuration Cabling accessories Cabling systemProfibus-DP bus Profibus-DP presentationAdvantys Distributed I/O, FTB splitter boxes Profibus-DP bus AddressingProfibus-DP bus connection cables InterBus bus extenson InterBus bus presentationInterBus bus extention InterBus bus extension Fieldbus characteristics Output characteristics Input/output characteristicsInput characteristics Splitter box typeMonobloc splitter boxes for DeviceNet bus For Profibus-DP bus Connection accessoriesFor CANopen/DeviceNet buses For InterBus busSeparate components For all bus typesFTB 1CNpppP0, FTB 1DNpppP0, FTB 1DPpppP0 FTB 1IBpppP1 4 elongated holeCANopen and DeviceNet buses Supply to splitter box Connector connectionSensor/actuator connection Bus input/Bus outputMain bus, bus input Local bus, bus inputLocal bus, bus output Main bus, bus outputMaximum number of digital I/O per bus module Degree of protection Bus connector typeBus modules FTM Industrial fieldbus type Diagnostics Per channel Connector typeResolution Splitter boxes FTM Digital inputs/outputsPrinciple Digital I/O splitter boxes Compact splitter boxesExpandable splitter boxes Analog I/O splitter boxesFTM 1DD FTM 1DE M12 and M8Functions CANopen bus configuration DeviceNet bus configuration PLC FTM 1DP One bus power supply status LED FTM 1CN/1DN FTM 1DP Cabling accessories for bus modules Internal cabling accessoriesBus module characteristics FTM 1CN10 FTM 1DN10 FTM 1DP10Characteristics Digital input/output splitter box characteristicsAnalog input/output splitter box characteristics FTM 1AE04C12C Bus modules for modular splitter boxesFTM 1CN10 CD-ROM For internal busFTX CBTL12 FTX ES00FTM 1DD16C12 Bus modules FTM 1pp10Splitter boxes FTM 1DE16C12 FTM 1Dp08C12Bus input/Internal bus output of splitter boxes Auxiliary power supplyInput/output connection for analog splitter boxes Signalling Switch mode power supplies ApplicationsNominal power Other characteristics MountingABL 7REQ ABL 7UEQ ABL 7UES ABL 7UPS Phaseo modular regulated power supplies Modular switch mode power supplies ABL 7RMInput circuit Technical characteristicsOperating characteristics Output circuitSchemes Upstream protection of power suppliesSelection GB2 CB pp GB2 CD pp GB2 DB pp GB2 CS ppScheme Modular regulated switch mode power supplies ABL 7RMPower supply ABL 7RMpppp ABL 7RMppppPhaseo regulated switch mode power supplies ABL 7 power suppliesABL 7UPS and ABL 7UES Using c 24Operating voltage ABL 7REQSelection of power supplies Selection according to application characteristics ABLABL 7CEM ABL 7RE ABL 7RP Mtbf ABL 7CEM DeratingGeneral rules to be complied with Series or parallel connection Load limitTemporary overloads ABL 7REQ power supplies protection of the power supply line Type of mains supplyABL 7RP single-phase regulated switch mode power supplies ABL 7CEM single-phase regulated switch mode power suppliesABL 7RE single-phase regulated switch mode power supplies ABL 7REQ 2-phase regulated switch mode power supplies7UPS24100 ABL 7UEQ24200 ABL 7UPS24200ABL 7UEppppp ABL 7RE2402/2403 ABL 7RE2405 ABL 7RE2410 ABL 7RP2403ABL 7CEM24ppp ABL 7REQ24ppp ABL 7RP1205/2405/4803 ABL 7UPSppppp and 7UESProduct Reference Index IP 67 I/O Splitter Boxes Page Schneider Electric Head office Schneider Electric

Splitter Boxes specifications

Quantum Instruments Splitter Boxes represent a significant advancement in the realm of optical signal processing and distribution. These sophisticated devices are designed to efficiently split and manage optical signals while ensuring minimal loss and optimal performance. One of the standout features of Quantum Instruments Splitter Boxes is their robust construction, which is designed to withstand harsh environmental conditions, making them suitable for both indoor and outdoor applications.

A key technology utilized in these splitter boxes is the advanced fiber optic splitting technology, which employs high-quality optical fibers to achieve precise signal distribution. This technology allows for uniform splitting ratios, ensuring that each output maintains the integrity of the original signal. Furthermore, Quantum Instruments has integrated low-loss components into their splitter boxes, which contribute to high transmission efficiency and reduced signal attenuation.

In terms of characteristics, Quantum Instruments Splitter Boxes are available in various configurations to meet diverse user needs. They support multiple input and output configurations, ranging from simple one-to-two splits to complex multi-channel setups. This versatility makes them ideal for a wide range of applications, from telecommunications and data centers to broadcasting and surveillance systems.

The boxes also feature user-friendly interfaces for easy installation and maintenance. Their modular design allows for straightforward scaling and customization, enabling users to adapt the system as their requirements evolve. Additionally, the splitter boxes are equipped with advanced diagnostics and monitoring capabilities to ensure optimal performance and quick identification of any potential issues.

Moreover, Quantum Instruments prioritizes energy efficiency in their designs. The splitter boxes are engineered to minimize power consumption while maximizing performance, making them a sustainable choice for modern optical networks.

Quantum Instruments Splitter Boxes not only embody cutting-edge technology but also emphasize reliability and practicality. With a commitment to innovation, they continue to set benchmarks in the industry, making them a preferred choice for professionals looking to enhance their optical signal distribution systems. Their combination of high-quality materials, advanced technology, and user-oriented design ensures that users receive unparalleled performance and value. As the demand for more efficient communication systems grows, Quantum Instruments remains at the forefront, delivering solutions that cater to the evolving needs of the industry.