Maintenance

MUFFLER

WARNING

Inspect periodically the muffler for loose fasteners, any damage or corrosion. If any sign of exhaust leakage is found, do not use the blower and have it repaired immediately.

Note that failing to do so may result in the engine catching on fire.

IMPORTANT

Before starting operation, always make sure to check if the muffler is properly held by two bolts to the cylinder. (Fastening Torque : 70~110kg·cm)

Even if one bolt out of three bolts is loose, the muffler may get loose during operation which may result in engine catching on fire.

SPARK ARRESTER

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. Periodically inspect and clean as necessary with a wire brush. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

AIR INLET SCREEN IMPORTANT

Blowing air is taken in from the air inlet screen. When air flow has dropped down during operation, stop the engine and inspect the air inlet screen for blocking by obstacles.

Note that failure to remove any such obstacles may result in the engine becoming overheated and damaged.

WARNING

Never use the blower without the screen at the air intake of the blower. Before each use, check that the screen is attached in place and is free from any damage.

12

Image 12
Contents HBZ2500 Safety First Contents Safety Precautions  4 Operator USE of BlowerWorking Condition Warning Avoid Noise Problem  6 Avoid Chances of Damage Symbols on the machine  7 Parts Location & Specifications Assembly 8  Model HBZ2500Fuel  9 Operation  10 Maintenance  11  12  MufflerSpark Arrester AIR Inlet Screen ImportantHOW to Install the AIR Inlet Screen to the Volute Cover Procedures to be Performed After Every 100 Hours of USEStorage  13 Troubleshooting guide  14 Check Probable Causes Action  15  Engine Group HBZ2500  16  17  Part Number Description QtyBlower Group HBZ2500  18  19  Manufacturers Warranty Coverage Model HBZ2500 Year Limited Warranty RedMax Modèle HBZ2500 Garantie limitée à 2 ans