RedMax HBZ2500 manual Troubleshooting guide,  14 , Check Probable Causes Action

Page 14

Troubleshooting guide

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel

fuel filter

fuel filter is clogged

carburetor adjustment screw

out of normal range

sparking (no spark)

spark plug is fouled/wet

 

plug gap is incorrect

spark plug

disconnected

drain it and with correct fuel

clean

adjust to normal range

clean/dry

correct (GAP: 0.6~0.7mm)

retighten

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

wash

When your unit seems to need further service, please consult with our RedMax service shop in your area.

14

Image 14
Contents HBZ2500 Safety First Contents Operator Safety Precautions 4  USE of BlowerWorking Condition Warning Avoid Chances of Damage Avoid Noise Problem 6  Symbols on the machine  7  8  Parts Location & SpecificationsAssembly Model HBZ2500Fuel  9 Operation  10 Maintenance  11 Spark Arrester  12 Muffler AIR Inlet Screen ImportantStorage HOW to Install the AIR Inlet Screen to the Volute CoverProcedures to be Performed After Every 100 Hours of USE  13 Check Probable Causes Action Troubleshooting guide 14   15  Engine Group HBZ2500  16  17  Part Number Description QtyBlower Group HBZ2500  18  19  Manufacturers Warranty Coverage Model HBZ2500 Year Limited Warranty RedMax Modèle HBZ2500 Garantie limitée à 2 ans