PYLE Audio BSV750 instruction manual Specification, Model

Page 2

SPECIFICATION

MODEL

BSV750

HORSE POWER

13

RATED/SURGE WATTS

7500/10,750

VOLTAGE

120/240

AMPERAGE

62.5/31.25

PHASE

SINGLE

FREQUENCY

60 Hz

ENGINE SPEED

3600 RPM

MAX. AMBIENT TEMP.

104° F

FUEL CAPACITY

7 GALLON

RUN TIME @ 50%/100%

9.4/5.4HRS

This product is not equipped with a spark arresting muffler. If the product will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of California. It is a violation of California statutes section 130050 and/or sections 4442 and 4443 of the Cal- ifornia Public Resources Code, unless the engine is equipped with a spark arrestor, as defined in section 4442, and maintained in effective working order. Spark arresters are also required on some U. S. Forest service land and may also be legally required under other statutes and ordinances.

This product may contain chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm. This warning is given in compliance with California Proposition 65, as detectable amounts of chemicals subject to proposition 65 may be contained in this product.

2 — ENG

Image 2
Contents Generator Specification ModelWarranty This Warranty is not Transferable and does not CoverRisk of Electrocution and Fire Safety Guidelines DefinitionsHazard What could Happen HOW to Prevent IT Risk of Electrocution and Fire cont’d Indoors ANY Risk of FireOr wall. do not Operate Unit Confined AreaRisk of Breathing Inhalation Hazard Risk of Unsafe Operation Risk of HOT SurfacesRisk of BURN-EXPLOSION Hazard Risk of Moving PartsRisk from Lifting Grounding the Generator AssemblyRemove Generator from Carton Obtaining Electricity from the Generator Extension Cord Wire Gauge Chart LengthTransfer Switch, a minimum of 10 gauge wiring must be used Operation To Start the Engine For Recoil StartPlace OFF/RUN/START switchBefore Start UP Follow the steps listed below before starting gener- atorConnecting Electrical Loads Stopping EngineMaintenance Storage Engine PreparationRunning Watts Starting Watts Wattage CalculationsDetermining Wattage Requirements Starting Wattage Requirements Volts X Amp = Watts Volts x 10 amps = 1200 wattsHousehold Wattage Calculator Appliance or Load Device Typical Device Wattage TotalTroubleshooting Guide ENG Wattage Wiring Battery Volt REG Engine Storage Operation Always Refer to the Manuals Supplied with this Unit