PYLE Audio BSV750 instruction manual Troubleshooting Guide

Page 20

TROUBLESHOOTING GUIDE

PROBLEM

 

CAUSE

 

CORRECTION

Engine will not start

1.

Low on fuel or oil..

1.

Add fuel or oil.

 

2.

Ignition switch in "Off" position.

2.

Turn to "ON" position.

 

3.

Faulty spark plug.

3.

Replace spark plug.

 

4.

Choke in wrong position.

4.

Adjust choke accordingly.

 

5.

Fuel shut-off valve in closed position.

5. Open fuel shut-off valve.

 

6.

Unit loaded during start-up.

6.

Remove load from unit.

 

7.

Spark plug wire loose.

7. Attach wire to spark plug.

 

8.

Faulty fuel shut-off solenoid.

8. Have an Authorized Service Center

 

 

 

 

replace.

 

 

 

 

 

No electrical output

1.

Faulty receptacle.

1.

Have an Authorized Service Center

 

 

 

 

replace.

 

2.

Circuit breaker kicked out.

2.

Depress and reset.

 

3.

Defective capacitor.

3.

Have an Authorized Service Center

 

 

 

 

replace.

 

4.

Faulty power cord.

4.

Repair or replace cord.

 

5.

GFCI switch breaker kicked out

5.

Depress and reset

Repeated circuit breaker

1.

Overload

1.

Reduce load.

tripping

2.

Faulty cords or equipment.

2.

Check for damaged, bare, or

 

 

 

 

 

frayed wires on equipment. Replace.

Generator overheating

No auto idle (if equipped)

DC does not have power with the circuit breaker depressed (if equipped)

1.Generator overloaded.

2.Insufficient ventilation.

1.Faulty solenoid.

2.Faulty idle control switch.

3.Faulty windings in stator.

4.Faulty circuit board.

5.Faulty wire harness.

1.Faulty rectifier.

2.Faulty windings in stator.

3.Faulty wire harness.

1.Reduce load.

2.Move to adequate supply of fresh air.

1.Have Service Center replace.

2.Have Service Center replace.

3.Have Service Center replace.

4.Have Service Center replace.

5.Have Service Center replace.

1.Have Service Center replace.

2.Have Service Center replace.

3.Have Service Center replace.

20 — ENG

Image 20
Contents Generator Specification ModelWarranty This Warranty is not Transferable and does not CoverRisk of Electrocution and Fire Safety Guidelines DefinitionsHazard What could Happen HOW to Prevent IT Risk of Electrocution and Fire cont’d Risk of Fire Or wall. do not Operate UnitIndoors ANY Confined AreaRisk of Breathing Inhalation Hazard Risk of Unsafe Operation Risk of HOT SurfacesRisk of BURN-EXPLOSION Hazard Risk of Moving PartsRisk from Lifting Grounding the Generator AssemblyRemove Generator from Carton Obtaining Electricity from the Generator Extension Cord Wire Gauge Chart LengthTransfer Switch, a minimum of 10 gauge wiring must be used Operation For Recoil StartPlace OFF/RUN/START switch Before Start UPTo Start the Engine Follow the steps listed below before starting gener- atorConnecting Electrical Loads Stopping EngineMaintenance Storage Engine Preparation Running Watts Starting Watts Wattage Calculations Determining Wattage Requirements Starting Wattage Requirements Volts X Amp = Watts Volts x 10 amps = 1200 wattsHousehold Wattage Calculator Appliance or Load Device Typical Device Wattage TotalTroubleshooting Guide ENG Wattage Wiring Battery Volt REG Engine Storage Operation Always Refer to the Manuals Supplied with this Unit