Addonics Technologies NASMS4HPMB manual Power On/Off Control, RAID Mode LEDs, Technical Support

Page 1

RAID Mode

LEDs

BIG 2

LEDs 1, 2 & 4 all OFF

BIG 4

4 ON, 2 & 1 OFF

FAST 2

2 ON, 4 & 1 OFF

FAST 4

1 ON, 4 & 2 OFF

SAFE FAST

4 & 2 ON, 1 OFF

SAFE 2

4 & 1 ON, 2 OFF

RAID 5

2 & 1 ON, 4 OFF

RAID 5 + S

4, 2 & 1 all ON

T E C H N O L O G I E S

Front

LED3 LED1

HPM eSATA

Power Status Power

Switch

LED4

LED2

Power

HPM

USB

LED

Health

Status

 

Back

USB Port

RAID Setting

Button

RAID Config Rotary Switch

eSATA Port

Connecting the Power Cable and Storage Tower to the Computer

a.Connect the power cord provided from the wall outlet to the back of the tower.

b.Make sure the power is off (power LED light should be off).

c.Connect the eSATA cable from the back of the tower to the eSATA port on the computer.

Power On/Off Control

a.A main power switch is located at the back of the tower. Turn the switch on. Another auxiliary switch is located on the front of the tower.

b.Make sure the power is off on the auxiliary switch (power LED light should be off).

c.Power on the tower.

User Guide

Mini Storage Tower

(NA3MS4HU2B / NASMS4HPMB)

www.addonics.com

v6.1.11

Technical Support

If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at:

Hours: 8:30 am - 6:00 pm PST

Phone: 408-453-6212

Email: http://www.addonics.com/support/query/