Addonics Technologies NA3MS4HU2B, NASMS4HPMB manual Removing Cover of Mini Storage Tower

Page 2

Removing Cover of Mini

Storage Tower

Loosen the 3 screws at the back of the tower using a Philips screwdriver by turning counter-clockwise. Separate the metal casing of the tower from the housing by lifting up the casing as shown on the photo.

Installing drives into the

Storage Tower

Step 1

 

Slide the storage device into the embedded

 

mounting bracket.

 

Step 2

 

Using 3.5” SATA Hard Disk Drives - Connect

 

the internal SATA data cable to the data port

 

of the hard drive then connect the 15-pin

 

SATA power connector to the power port on

 

the hard drive.

Hard Disk

Step 3

 

Secure the hard disk by using screws

 

provided. Repeat the above procedure for

 

additional hard drives.

 

Setting RAID on the Hardware Port Multiplier (HPM)

-

+

eSATA Status

 

 

-

+

USB Status

 

 

-

+

PM Power

SATA Port 4

 

-

+

PM Health

 

 

 

-

+ HD3 PWR & Access

 

 

-

+

HD2 PWR & Access

SATA Port 1

Pin 1

 

 

-

+

HD1 PWR & Access

 

SATA Port 2

-

+

 

 

HD0 PWR & Access

 

SATA Port 3

LED Pins

1

1.Set the Rotary switch to the RAID mode required.

2.Push the RAID setting button with a ballpoint pen while the tower is turned off.

Note: Do not use paper clip or sharp object. Use a ballpoint pen to press the raid setting button.

3. While holding the RAID setting button, turn on the tower and continue to hold for at least 5 seconds.

Note: The LED's for SATA and USB will blink while pressing on the raid setting button. Once the button is release, the PM Health LED will blink for 4-6 times then stops. This indicates the raid was setup correctly. Otherwise, the PM Health LED will remain lit up indicating incorrect raid setup.

Instruction for Special RAID Modes:

BIG 2 - 2 Drives Spanned

oNote: Do not connect more than 2 SATA drives to the HPM. Doing so will hang the system when you configure the raid.

oFor SATA drives with different capacities, the HPM will use the smallest drive capacity of the 2 drives connected to create the total partition size.

FAST 2 - 2 Drives Striped

oNote: Do not connect more than 2 SATA drives to the HPM. Doing so will hang the system when you configure the raid.

Verify RAID Setting on the HPM

Note: Disconnect the HPM from host when verifying the RAID setting.

It is assumed that you have already connected the SATA drives and set up the raid mode when verifying the raid setting.

1.Turn on power for the tower.

2.Push the RAID setting button with the tool provided. Using the table below, verify if the LEDs are lighting up. The selected LEDs will light up for 2 seconds followed by a blink and cycles back.