Husqvarna 225L, 227L/LD, 240 L manual Muffler, Cooling system, Air filter, Cleaning the air filter

Page 18

MAINTENANCE

Muffler

NOTE!

Some mufflers are fitted with a catalytic converter. See

Technical data“ to see whether your machine is fitted with a catalytic converter.

The muffler is designed to dampen the noise level and to direct the exhaust fumes away from the user. The exhaust fumes are hot and can contain sparks, which can result in fire if the exhaust fumes are directed towards a dry and inflammable material. Some mufflers are equipped with a special spark arrest screen. If your machine is fitted with this type of screen it should be cleaned regularly. This is done using a wire brush. On mufflers without a catalytic converter the screen should be cleaned weekly, or replaced if necessary. On mufflers fitted with a catalytic converter the screen should be checked and cleaned monthly. If the screen is damaged it should be replaced. If the screen is frequently blocked, this can be a sign that the function of the catalytic converter is impaired. Contact your dealer to inspect the muffler. A blocked screen will cause the engine to overheat resulting in damage to the cylinder and piston. Also see under “Maintenance”.

NOTE!

Never use a machine with a defective muffler.

Cooling system

To maintain as low opera- ting temperature as possible the engine is equipped with a cooling system.

The cooling system consists of:

1.An air intake on the starter unit.

2.Cooling fins on the flywheel.

3.Cooling fins on the cylinder

4.Cylinder cover (leads cold air onto the cylinder).

Clean the cooling system using a brush at least once a week, in difficult conditions more often.

A dirty or blocked cooling system leads to the engine overheating resulting in damage to the cylinder and piston.

Air filter

The air filter should be cleaned regularly removing dust and dirt to avoid:

carburetor malfunction

starting problems

reduced engine power

unnecessary wear to engine parts

abnormal fuel consumption

Clean the filter after every 25 hours or more regularly if operating conditions are exceptionally dusty.

4

3

2

1

!WARNING!

Mufflers fitted with catalytic converters become extremely hot during use and after stopping. This also applies at idling speeds. Contact can result in burns to the skin. Be observant to the risk of fire!

Cleaning the air filter

Dismantle the air filter cover and remove the air filter. Wash in clean, warm soapy water. Ensure that the filter is dry before refitting. An air filter used for a long period of time can never be cleaned completely. Therefore it is necessary to replace the filter from time to time with a new filter. A damaged air filter must always be replaced.

18 – English

Image 18
Contents 225L/LD 227L/LD 232L 240L 101 89Symbol Explanation SymbolsMax 10000 rpm Contents Safety Instructions Machine‘s safety equipmentPersonal protective equipment Cutting Equipment Vibration damping systemMuffler Locking nutMaintenance Cutting equipment Trimmer headStart General safety instructionsFuel safety Transport and storageGeneral working instructions Basic safety precautionsGrass trimming using the trimmer head Basic working techniquesClearing TrimmingSweeping What is WHAT? What is what on the trimmer?Assembly Assembly of the trimmer headAssembling other guards and cutting equipment AssemblingDismantling Fuel Handling Fuel mixtureFuelling Start and Stop Control before startingStart and stop Maintenance CarburetorFinal setting of the idling speed T Correctly adjusted carburetorHigh speed needle Cooling system Cleaning the air filterMuffler Air filterAngle gear Maintenance scheduleSpark plug Two-part shaftTechnical Data Technical data 225L/LD 227L/LD 232LTechnical data 240L «*2¤5m¬ English 1998W51