Dashboard Display & Functions
Display Items
Refer to Figures 3.
A. FUEL LEVEL
Indicates the amount of fuel in the fuel tank. Left is empty; right is full.
B. HOUR METER / CLOCK / SERVICE INDICATOR
Displays the clock, hour meter, and maintenance reminder.
C. SELECT BUTTON
Used to set the clock and reset the maintenance reminder.
D. SET BUTTON
Used to set the clock and reset the maintenance reminder.
E. PTO LIGHT
Indicates the PTO switch is in the ON position.
F. CRUISE CONTROL LIGHT
Indicates that the cruise control is engaged.
G. LOW OIL PRESSURE LIGHT
Indicates that the engine oil pressure is low. The light will turn on when the tractor is first started and then go out. IF THIS LIGHT TURNS ON WHILE THE TRACTOR IS IN USE, TURN THE ENGINE OFF IMMEDIATELY. Contact your authorized dealer for service.
H. LOW VOLTAGE LIGHT
Indicates that the electrical system voltage is low. The light will turn on when the tractor is first started and then go out. IF THIS LIGHT TURNS ON WHILE THE TRAC-
TOR IS IN USE, TURN THE ENGINE OFF IMMEDIATE- LY. Contact your authorized dealer for service.
Features & Controls
| A |
| B |
|
|
| D |
|
|
| C |
| Cruise |
| PTO |
H | G | F | E |
Figure 3. Dashboard Display - Select Models
Functions
DASHBOARD DISPLAY MODELS (SEE FIGURE 3)
Display Total Running Hours - When the key switch is first turned to the RUN position, all warning indicators will light and the total running hours will be displayed. Be sure all lights are functioning.
Display PTO Hours - Turn the key OFF, engage the PTO, and turn the key to RUN (engine off).
Set the Clock - Start the engine, leave the engine run- ning. Depress the select button (C) for three (3) seconds and release. Depress set button and HOLD to advance time. Depress select button to select minutes. Depress and HOLD set button (D) to advance time. Leave alone for 5 seconds and clock will activate. Shut off engine.
Demonstration Mode - With the engine off, hold down the set button (D) and turn the key switch to RUN.
Maintenance Reminder - A maintenance reminder will display in the information window (B) after the first 5 hours of operation, and then after every 50 hours. The reminder will automatically reset after 5 hours. The reminder can be manually reset by turning the key switch from OFF to RUN (with engine off) and then depressing the set (D) and select (C) buttons simultaneously for 5 seconds.
12 Volt Power Outlet
(Select Models)
CAUTION
Avoid Injury. Safe operation requires your full attention. Do not wear radio or music headphones while operating machine.
The
Note: Operating a
13