Indicators, Controls And Connections

 

1

LED meters with a range from -13 dB to 0 dB

 

2

CLIP indicators

 

3

TEST button for checking and reset function

 

4

STANDBY indicator

 

5

PROTECT indicator

 

6

GROUND FAULT indicator

 

7

READY indicator

 

8

Air inlets

 

9

POWER ON switch

 

10

AC MAINS INPUT connector

 

11

Mains fuse

 

12

VOLTAGE SELECTOR switch

 

13

REMOTE CONTROL connectors

 

14

STATUS indicator

 

15

INPUT connectors 1-4

 

16

ROUTING switch for INPUT 1-4

 

17

Device address label field

 

18

ADDRESS selector switch

 

19

POWER OUTPUT

 

20

Device output configuration label field

 

21

Air outlets

 

22 CIRCUIT TO CHASSIS SWITCH

 

23 DC INPUT 24 V =

A

Rear plate screws:

6 oval-head sheet-metal screws 3.5 x 6.5 zinc-coated DIN 7981

B heat-sink-mounting:

4 oval-head sheet-metal screws 3.5 x 9.5 zinc-coated DIN 7981

C

PCB-mounting:

9 oval-head screws M3 x 12 nickel-plated DIN 7985

D

socket-mounting:

8 oval-head screws PT-KA 30 x 8 WN-1412EJOT black, zinc-coated

21

Image 3
Contents Features Power Amplifier DPAFor US and Canada only Important Safety InstructionsCircuit ⊥ to Chassis Switch Indicators, Controls And ConnectionsTable of Contents Before Initial Operation 3.1 Mains Operation Installation NotesUtilization Amplifier has to be protected againstInputs Input 1 to Input Battery Operation 24 V DCOutputs Power Output for the connection of 100 V loudspeaker systemsPower Output 100 V Double Output Power Monitor outputIntegrated Remote Module Indicators And Fault Notification 7.1 Standby Indicator Ready IndicatorProtect Indicator Ground Fault Indicator Meter Instruments And Clip IndicatorsStatus Indicator To Install The NRS 90206 Proceed As Follows see diagram NRS 90207 Ground Fault Surveillance To Install The NRS 90207 Proceed As Follows see diagramChecking The Function Of The NRS NRS 90208 Input Transformer For Floating, Balanced Inputs Retrofitting The NRS 90208 On The Printed Board AssemblyRemove the input printed board assembly 81331 see diagram Installation of the rear panelFlightcase Or 19-Rack System Installation To Install The NRS 90227 Proceed As Follows see diagramFuses Ground Lift Switch Circuit ⊥ to Chassis SwitchPage DPA 4411 Specifications NRS 90227 monitor output transformer NRS 90207 ground fault surveillance for four outputsExtension kits for the DPA NRS 90208 input transformer per single input