mains operation remote control ON/OFF

battery operation remote control ON/OFF

monitoring and fault message transmission via the PROMATRIX Manager DPM 4000; in accordance to DIN EN 60849 standard

thermal overload of the mains transformer

thermal overload of power output stages 1 to 4

monitoring of the functioning of the power output stages 1 to 4 via pilot tone signal (optional, only with NRS 90206 installed)

ground fault detection for loudspeaker lines 1 to 4 (optional, only with NRS 90207 installed)

measuring of input and output level peaks 1 to 4

measuring of output voltages / levels of the power outputs 1 to 4

measuring of output currents of the power outputs 1 to 4

monitoring of connected loads 1 to 4 via current-voltage-measuring

recognition of amplifier type including user-definable name

reading of software revision of the remote module

reading of error flags

reading of the output configuration

recognition of extensions NRS 90206 and NRS 90207

switching the input monitor / output monitor 1 to 4 to the monitor bus

pilot tone signal ON/OFF (optional, only with NRS 90206 installed)

ground fault error flags reset

Note Prior to the first operation of the amplifier DPA 4411, you have to set the amplifier address using the two Hexadecimal Code switches ADDRESS (18) (refer to the PROMATRIX handbook) and using a waterproof marker pen mark the setting in the ADDRESS label field on the rear panel of the appliance.

By sending the corresponding command via the serial port REMOTE CONTROL (13) of the remote module, this function is activated from the PROMATRIX Manager DPM 4000 (see PROMATRIX handbook).

7.Indicators And Fault Notification 7.1 STANDBY Indicator

When correctly connected and with mains voltage and/or battery voltage present, the green STANDBY indicator (4) lights.

7.2 READY Indicator

The power amplifier DPA 4411 provides a power-on delay of approximately 3 s to prevent switch clicks from becoming audible. If after this period of time no faulty condition has been detected, the green READY indicator (7) lights and the mute-relays pull. When thermal overload of the mains transformer or of one of the power output stages is detected, the corresponding green READY indicator (7) will not light and the according mute-relay drops. If, with the NRS 90206 extension installed the pilot-threshold (see paragraph 9.1) is declined, the corresponding green READY indicator (7) goes out but the amplifier stays operational and a fault message gets transmitted to the PROMATRIX Manager DPM 4000.

7.3 PROTECT Indicator

In case of thermal overload of the mains transformer or of a power output stage is detected, the red PROTECT indicator (5) will light. During thermal overload of the mains transformer, all mute-relays drop while during thermal overload of a power output stage, only the according mute-relay drops. After the mains transformer or the power amplifier have regained their normal temperature, the red PROTECT indicator (5) automatically goes out and the appliance recovers normal operation mode. The faulty condition could have been caused by either overload, too high environmental temperature, or by an error in the ventilation system. A fault-message is transmitted to the PROMATRIX Manager DPM 4000.

27

Image 9
Contents Features Power Amplifier DPAFor US and Canada only Important Safety InstructionsCircuit ⊥ to Chassis Switch Indicators, Controls And ConnectionsTable of Contents Utilization Installation NotesAmplifier has to be protected against Before Initial Operation 3.1 Mains OperationInputs Input 1 to Input Battery Operation 24 V DCOutputs Power Output for the connection of 100 V loudspeaker systemsPower Output 100 V Double Output Power Monitor outputIntegrated Remote Module Indicators And Fault Notification 7.1 Standby Indicator Ready IndicatorProtect Indicator Ground Fault Indicator Meter Instruments And Clip IndicatorsStatus Indicator To Install The NRS 90206 Proceed As Follows see diagram NRS 90207 Ground Fault Surveillance To Install The NRS 90207 Proceed As Follows see diagramChecking The Function Of The NRS Remove the input printed board assembly 81331 see diagram Retrofitting The NRS 90208 On The Printed Board AssemblyInstallation of the rear panel NRS 90208 Input Transformer For Floating, Balanced InputsFlightcase Or 19-Rack System Installation To Install The NRS 90227 Proceed As Follows see diagramFuses Ground Lift Switch Circuit ⊥ to Chassis SwitchPage DPA 4411 Specifications Extension kits for the DPA NRS 90207 ground fault surveillance for four outputsNRS 90208 input transformer per single input NRS 90227 monitor output transformer