diagram 10 Printed board assembly 81331 showing the position of the input transformers NRS 90208
9.4 Monitor Output Transformer NRS 90227 Offering A Floating, Balanced MONITOR Output
In case a floating MONITOR output is needed, the monitor amplifier’ output is prepared for retrofitting an output transformer. Herefore, you will need the extension kit NRS 90227.
Caution |
| Unplug the mains cord and disconnect batteries before opening the appliance! |
|
|
|
9.4.1 To Install The NRS 90227 Proceed As Follows: (see diagram 10)
-for opening the appliance, please remove the 9 screws on the top of the appliance that lock the cover plate.
-
-disconnect the resistors R95, R96, R97 and R101 before installing the monitor output transformer.
-mount the monitor output transformer on the printed board assembly 81331; in doing so, polarity is of no importance, since the transformer is balanced.
reinstall the input printed board assembly 81331 following the description in paragraph 9.3.1.
-closing the appliance: use the 9 screws M3 x 6 DIN 7500 to reattach the cover plate.
10. 19"-Flightcase Or 19"-Rack System Installation
Caution |
| Operating the DPA 4411 without |
|
|
|
When incorporating the DPA 4411 into a 19" flightcase or 19" rack system, make sure to leave room for sufficient
mmof space should be left above a rack system to guarantee sufficient air circulation. Since, during the operation of the DPA 4411 the environmental temperature within the rack closet may increase by about 10° C, minding the maximum allowable temperature values for other equipment that is installed into the same rack system or enclosure is of major importance.
Note
For
32