Snapper 6200 manual Troubleshooting, Problem Cause Correction

Page 15

Snapper 6200W Portable Generator

TROUBLESHOOTING

Problem

Cause

Correction

 

 

 

 

 

 

1.

One of the circuit breakers is

1.

Reset circuit breaker.

 

 

open.

 

 

No AC output is available, but

2.

Fault in generator.

2.

Contact Authorized service facility.

3.

Poor connection or defective cord

3.

Check and repair.

generator is running.

 

set.

 

 

 

 

 

 

 

4.

Connected device is bad.

4.

Connect another device that is in

 

 

 

 

good condition.

 

 

 

 

 

Generator runs good at no-load

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

 

 

 

but "bogs" down" when loads are

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

connected.

3.

Shorted generator circuit.

3.

Contact Authorized service facility.

 

 

 

 

 

 

Generator will not start; or starts

1.

Failed battery.

1.

Replace battery.

2.

Low oil level.

2.

Fill crankcase to proper level or

and runs rough.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

 

 

Generator shuts down during

1.

Out of gasoline.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level or

operation.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 

15

Image 15
Contents Watt Generator Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Electric Start AssemblyCarton Contents Check Battery / Attach Negative Battery WireRefer to and install the wheel kit as follows Install Wheel KitAdd Engine Oil When Adding FuelBefore Starting the Engine Add FuelGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundDo not Overload the GENERATOR. See Don’t Overload Generator Connecting Electrical LoadsOperating Generator Starting the Engine120/240 Volt AC, 30 Amp, Locking Receptacle Battery ChargerReceptacles Stopping the EngineExample Power ManagementDont Overload Generator CapacityGeneral Maintenance Recommendations SpecificationsOther Storage Tips StorageGenerator Storage Engine StorageProblem Cause Correction TroubleshootingSnapper 6200W Portable Generator Snapper Owner Warranty Policy Effective August 1 About your equipment warrantyEquipment Consumer Use Commercial Use Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Tomacorriente con Dispositivo de Seguridad de Conozca SU GeneradorTapa del Depósito del Aceite Llene el motor con aceite Tomacorriente Dobles de 120 Voltios AC, 20 AmpContenido de la Caja MontajeArranque Eléctrico Desembalaje del GeneradorInstale el Juego de Ruedas Como Sigue Figura Instale el Juego de RuedasCuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorNo Sobrecargue EL GENERADOR.Vea No Sobrecargue Generador Operando EL GeneradorEncienda el Motor Conexion De Cargas Electricas120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Receptáculos PrecauciónCargador DE Batería Parado Del MotorEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaRecomendaciones Generales DE Mantenimiento EspecificacionesOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Problemo Accion CausaAcerca de la seguridad de su equipo Efectiva desde el 1 ro de AgostoEquipo Para Uso Del Consumidor Para Uso Comercial Garantía Limitada