Seller warrants that the firmware will execute the programming instructions provided by Seller, and that the Goods manufactured or Serv- ices provided by Seller will be free from defects in materials or workmanship under normal use and care until the expiration of the appli- cable warranty period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller, whichever period expires first. Consumables, such as glass electrodes, membranes, liquid junctions, elec- trolyte, o-rings, catalytic beads, etc., and Services are warranted for a period of 90 days from the date of shipment or provision.

Products purchased by Seller from a third party for resale to Buyer ("Resale Products") shall carry only the warranty extended by the orig- inal manufacturer. Buyer agrees that Seller has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement and shipping of the Resale Products.

If Buyer discovers any warranty defects and notifies Seller thereof in writing during the applicable warranty period, Seller shall, at its option, promptly correct any errors that are found by Seller in the firmware or Services, or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Seller to be defective, or refund the purchase price of the defective portion of the Goods/Services.

All replacements or repairs necessitated by inadequate maintenance, normal wear and usage, unsuitable power sources, unsuitable envi- ronmental conditions, accident, misuse, improper installation, modification, repair, storage or handling, or any other cause not the fault of Seller are not covered by this limited warranty, and shall be at Buyer's expense. Seller shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by an authorized Seller representative. All costs of dismantling, reinstallation and freight and the time and expenses of Seller's personnel for site travel and diagnosis under this warranty clause shall be borne by Buyer unless accepted in writing by Seller.

Goods repaired and parts replaced during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller. Except as otherwise expressly provided in the Agreement, THERE ARE NO REPRESEN-

TATIONS OR WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES.

RETURN OF MATERIAL

Material returned for repair, whether in or out of warranty, should be shipped prepaid to:

Emerson Process Management

Rosemount Analytical

2400 Barranca Parkway

Irvine, CA 92606

The shipping container should be marked:

Return for Repair

Model _______________________________

The returned material should be accompanied by a letter of transmittal which should include the following information (make a copy of the "Return of Materials Request" found on the last page of the Manual and provide the following thereon):

1.Location type of service, and length of time of service of the device.

2.Description of the faulty operation of the device and the circumstances of the failure.

3.Name and telephone number of the person to contact if there are questions about the returned material.

4.Statement as to whether warranty or non-warranty service is requested.

5.Complete shipping instructions for return of the material.

Adherence to these procedures will expedite handling of the returned material and will prevent unnecessary additional charges for inspection and testing to determine the problem with the device.

If the material is returned for out-of-warranty repairs, a purchase order for repairs should be enclosed.

Warranty

33

Image 39
Contents Clarity II T56 Turbidimeter Clarity II T56 Clarity II T56 Turbidimeter About This Document Contents Table of Contents cont’d Features and Applications Description and SpecificationsSpecifications General Listed T56 Turbidity System Components Ordering InformationGeneral Information InstallationInstallation Unpacking and InspectionPanel Mount Wall / Surface Mount Installation Debubbler Assembly Debubbler and Flow Chamber Sensor Installation SensorGeneral WiringPower, Output, and Sensor Connections Preparing Conduit OpeningsPreparing Sensor Cable Sensor Sensor wiring to signal boardsImportant Note Function keys Display and OperationUser Interface Instrument KeypadProcess Measurements Main DisplayNavigation Keys Alpha-numeric KeypadMenu System Fault and Warning bannerPN-51-T56 May This page left blank intentionally Configuring and Ranging the Current Outputs Setting a Security CodeProgramming the Analyzer Basics Security Access Using HoldResetting Factory Default Settings ENTER/MENU Programming Alarm RelaysClarity II T56 Programming Turbidity Programming Measurements IntroductionTurbidity Measurement Programming PN-51-T56 May This page left blank intentionally Calibration Calibration IntroductionTurbidity Slope Calibration Turbidity Standardize Calibration TurbidityGrab Calibration Turbidity Sensor MaintenanceCleaning the sensor OverviewReplacing the Lamp/LED Board Debubbler and Measuring Chamber Cleaning the orificeLocation Description Part List of Replacement PartsWarranty Repair Non-Warranty RepairReturn of Material Appendix Dilution Volume Final Volume for FactorWarranty Certification Clarity II T56 PN-51-T56 May This page left blank intentionally Clarity II T56 RosemountAnalytical.com

PN-51-T56 specifications

The Emerson PN-51-T56 is a sophisticated and versatile process control valve designed to meet the demands of various industrial applications. This model is known for its robust performance, reliability, and advanced features that enhance its functionality and efficiency in process control.

One of the main features of the PN-51-T56 is its globe valve design, which allows for excellent flow regulation and precise control over fluid dynamics. The valveā€™s construction is designed to minimize pressure drop while ensuring high flow capacity, making it ideal for both liquid and gas applications in industries such as oil and gas, chemical processing, and water treatment.

The PN-51-T56 incorporates Emerson's latest technologies, including digital valve control systems. These systems enable seamless integration with existing control networks, allowing for real-time performance monitoring and diagnostics. With smart technologies, operators can optimize valve performance, reduce downtime, and improve overall process efficiency.

In terms of characteristics, the PN-51-T56 features a wide range of sizing options, providing versatility in various applications. It is available in different materials, allowing users to select the most appropriate material for their specific media and environmental conditions. The valve is built to withstand extreme temperatures and pressures, ensuring durability and longevity even in the most demanding situations.

Additionally, the valve's design considers maintenance ease, featuring accessible components that simplify repairs and periodic maintenance. This design philosophy minimizes operational interruptions and contributes to lower lifecycle costs.

Another key characteristic of the PN-51-T56 is its compliance with international standards and regulations, ensuring that users can rely on its safety and performance in critical applications.

In summary, the Emerson PN-51-T56 combines innovative technology with a robust design to deliver precise control in process applications. Its superior performance, durability, and ease of integration make it a preferred choice for industries requiring reliable process control solutions. With ongoing advancements in automation and digitalization, the PN-51-T56 positions itself as an essential tool for optimizing process efficiency and effectiveness in modern industrial settings.