Emerson PN-51-T56 instruction manual Preparing Conduit Openings, Preparing Sensor Cable

Page 18

Instruction Manual

Clarity II T56

PN-51-T56

May 2012

 

 

3.2Preparing Conduit Openings

There are six conduit openings in all configurations of T56. (Note that four of the openings will be fitted with plugs upon shipment.)

Conduit openings accept 1/2-inch conduit fittings or PG13.5 cable glands. To keep the case water- tight, block unused openings with NEMA 4X or IP65 conduit plugs.

NOTE:

Use watertight fittings and hubs that comply with your requirements. Connect the conduit hub to the conduit before attaching the fitting to the analyzer.

3.3Preparing Sensor Cable

The T56 is intended for use with all Rosemount Analytical sensors. Refer to the sensor installation instructions for details on preparing sensor cables.

3.4Power, Output, and Sensor Connections

3.4.1Power wiring

Two Power Supplies are offered for the T56:

a.24VDC (20 – 30V) Power Supply (-02 ordering code)

b.85 – 265 VAC Switching Power Supply (-03 ordering code)

AC mains leads and 24VDC leads are wired to the Power Supply board which is mounted vertically on the left side of the main enclosure cavity. Each lead location is clearly marked on the Power Supply board. Wire the power leads to the Power Supply board using the lead markings on the board.

The grounding plate is connected to the earth terminal of the -03 (85-265VAC) power supply. The green colored screws on the grounding plate are intended for connection to some sensors to minimize radio frequency interference. The green screws are not intended to be used for safety purposes.

3.4.2Current output wiring

All instruments are shipped with four 4-20mA current outputs. Wiring locations for the outputs are on the Main board which is mounted on the hinged door of the instrument. Wire the output leads to the correct position on the Main board using the lead markings (+/positive, -/negative) on the board. Male mating connectors are provided with each unit.

3.4.3Alarm relay wiring

Four alarm relays are supplied with the switching power supply (85 to 265VAC, -03 order code) and the 24VDC power supply (20-30VDC, -02 order code). Wire the relay leads on each of the independent relays to the correct position on the power supply board using the printed lead markings (NO/Normally Open, NC/Normally Closed, or Com/Common) on the board.

12

Wiring

Image 18
Contents Clarity II T56 Turbidimeter Clarity II T56 Clarity II T56 Turbidimeter About This Document Contents Table of Contents cont’d Description and Specifications Features and ApplicationsSpecifications General Listed Ordering Information T56 Turbidity System ComponentsUnpacking and Inspection InstallationInstallation General InformationPanel Mount Wall / Surface Mount Installation Debubbler Assembly Debubbler and Flow Chamber Installation Sensor SensorWiring GeneralPower, Output, and Sensor Connections Preparing Conduit OpeningsPreparing Sensor Cable Sensor wiring to signal boards SensorImportant Note Instrument Keypad Display and OperationUser Interface Function keysAlpha-numeric Keypad Main DisplayNavigation Keys Process MeasurementsFault and Warning banner Menu SystemPN-51-T56 May This page left blank intentionally Configuring and Ranging the Current Outputs Setting a Security CodeProgramming the Analyzer Basics Security Access Using HoldResetting Factory Default Settings Programming Alarm Relays ENTER/MENUClarity II T56 Programming Turbidity Programming Measurements IntroductionTurbidity Measurement Programming PN-51-T56 May This page left blank intentionally Calibration Calibration IntroductionTurbidity Slope Calibration Turbidity Standardize Calibration TurbidityGrab Calibration Turbidity Overview MaintenanceCleaning the sensor SensorReplacing the Lamp/LED Board Cleaning the orifice Debubbler and Measuring ChamberList of Replacement Parts Location Description PartWarranty Repair Non-Warranty RepairReturn of Material Dilution Volume Final Volume for Factor AppendixWarranty Certification Clarity II T56 PN-51-T56 May This page left blank intentionally Clarity II T56 RosemountAnalytical.com

PN-51-T56 specifications

The Emerson PN-51-T56 is a sophisticated and versatile process control valve designed to meet the demands of various industrial applications. This model is known for its robust performance, reliability, and advanced features that enhance its functionality and efficiency in process control.

One of the main features of the PN-51-T56 is its globe valve design, which allows for excellent flow regulation and precise control over fluid dynamics. The valveā€™s construction is designed to minimize pressure drop while ensuring high flow capacity, making it ideal for both liquid and gas applications in industries such as oil and gas, chemical processing, and water treatment.

The PN-51-T56 incorporates Emerson's latest technologies, including digital valve control systems. These systems enable seamless integration with existing control networks, allowing for real-time performance monitoring and diagnostics. With smart technologies, operators can optimize valve performance, reduce downtime, and improve overall process efficiency.

In terms of characteristics, the PN-51-T56 features a wide range of sizing options, providing versatility in various applications. It is available in different materials, allowing users to select the most appropriate material for their specific media and environmental conditions. The valve is built to withstand extreme temperatures and pressures, ensuring durability and longevity even in the most demanding situations.

Additionally, the valve's design considers maintenance ease, featuring accessible components that simplify repairs and periodic maintenance. This design philosophy minimizes operational interruptions and contributes to lower lifecycle costs.

Another key characteristic of the PN-51-T56 is its compliance with international standards and regulations, ensuring that users can rely on its safety and performance in critical applications.

In summary, the Emerson PN-51-T56 combines innovative technology with a robust design to deliver precise control in process applications. Its superior performance, durability, and ease of integration make it a preferred choice for industries requiring reliable process control solutions. With ongoing advancements in automation and digitalization, the PN-51-T56 positions itself as an essential tool for optimizing process efficiency and effectiveness in modern industrial settings.