7-2. Optional Generator Power Receptacles

Notes

! If unit does not have GFCI re- ceptacles, use GFCI- protected extension cord.

Combined output of all receptacles limited to 10 kVA/kW rating of the generator.

GFCI Receptacle Option

1120 V 20 A AC GFCI Recep- tacles GFCI2 and GFCI3

1GFCI2 and GFCI3 supply 60 Hz single-phase power at weld/power speed. Maximum output from GFCI2 or GFCI3 is 2.4 kVA/kW. Cir- cuit protection is the same as stan- dard receptacles.

If a ground fault is detected, the GFCI Reset button pops out and the circuit opens to disconnect the faulty equipment. Check for damaged tools, cords, plugs, etc. connected to the receptacle. Press button to reset receptacle and resume operation.

. At least once a month, run engine at weld/power speed and press Test button to verify GFCI is working properly.

Ref. 226 427-A