SECTION 5 − INSTALLATION
5-1. Installing Welding Generator
Movement
OR
Location / Airflow Clearance
OR | OR |
|
18in
(460 mm)
| 18 in |
18 in | (460 mm) |
(460 mm)
18 in | 18 in | |
(460 mm) | ||
(460 mm) | ||
| ||
Mounting |
|
OR
1
Grounding 2
GND/PE | 3 |
|
! | Do not lift unit from end. |
! Do not weld on base. Welding | |
| on base can cause fuel tank fire |
| or explosion. Bolt unit down |
| using holes provided in base |
! Always securely fasten weld- | |
| ing generator onto transport |
| vehicle or trailer and comply |
| with all DOT and other applica- |
| ble codes. |
! | Do not mount unit by support- |
ing the base only at the four mounting holes. Do not use flexible mounts. Use cross- supports to adequately sup- port unit and prevent damage to base.
! Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.
! | If unit does not have GFCI re- |
ceptacles, use
! | Do not install unit where air |
flow is restricted or engine may overheat.
Mounting:
1
Mount unit on flat surface or use
Grounding:
2Equipment Grounding Terminal (On Front Panel)
3Grounding Cable (Not Supplied)
4Metal Vehicle Frame
Connect cable from equipment ground terminal to metal vehicle frame. Use #10 AWG or larger insu- lated copper wire.
.Electrically bond generator frame
to vehicle frame by
! Bed liners, shipping skids, and some running gears insulate the welding generator from the vehicle frame. Always connect a ground wire from the genera- tor equipment grounding ter- minal to bare metal on the ve- hicle frame as shown.
4 | install2 2007−04 − Ref. 800 652 / Ref. 800 |