SECTION 5 − INSTALLATION

5-1. Installing Welding Generator

Movement

OR

Location / Airflow Clearance

OR

OR

 

18in

(460 mm)

 

18 in

18 in

(460 mm)

(460 mm)

18 in

18 in

(460 mm)

(460 mm)

 

Mounting

 

OR

1

Grounding 2

GND/PE

3

 

!

Do not lift unit from end.

! Do not weld on base. Welding

 

on base can cause fuel tank fire

 

or explosion. Bolt unit down

 

using holes provided in base

! Always securely fasten weld-

 

ing generator onto transport

 

vehicle or trailer and comply

 

with all DOT and other applica-

 

ble codes.

!

Do not mount unit by support-

ing the base only at the four mounting holes. Do not use flexible mounts. Use cross- supports to adequately sup- port unit and prevent damage to base.

! Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.

!

If unit does not have GFCI re-

ceptacles, use GFCI-protected extension cord.

!

Do not install unit where air

flow is restricted or engine may overheat.

Mounting:

1 Cross-Supports

Mount unit on flat surface or use cross-supports to support base.

Grounding:

2Equipment Grounding Terminal (On Front Panel)

3Grounding Cable (Not Supplied)

4Metal Vehicle Frame

Connect cable from equipment ground terminal to metal vehicle frame. Use #10 AWG or larger insu- lated copper wire.

.Electrically bond generator frame

to vehicle frame by metal-to-metal contact.

! Bed liners, shipping skids, and some running gears insulate the welding generator from the vehicle frame. Always connect a ground wire from the genera- tor equipment grounding ter- minal to bare metal on the ve- hicle frame as shown.

4

install2 2007−04 − Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712

OM-945 Page 16

Page 20
Image 20
Hobart Welding Products OM-945 manual Installation, Installing Welding Generator