5-4. Activating The Dry Charge Battery (If Applicable)
! Always wear a face shield,
3
2
1
rubber gloves and protec- tive clothing when working on a battery.
Remove battery from unit.
1Vent Caps
2Sulfuric Acid Electrolyte (1.265 Specific Gravity)
3Well
Fill each cell with electrolyte to bottom of well (maximum).
! Do not overfill battery cells.
Wait ten minutes and check elec- trolyte level. If necessary, add elec- trolyte to raise to proper level. Reinstall vent caps.
4 Battery Charger
! |
Read and follow all instruc-
tions supplied with battery charger.
4
5 A For 30 Minutes
OR+
−
Tools Needed: | 30 A For 12 Minutes |
|
Charge battery for 12 minutes at 30 amperes or 30 minutes at 5 am- peres. Disconnect charging cables and install battery.
.When electrolyte is low, add only distilled water to cells to maintain proper level.
drybatt1 6/05 −
5-5. Connecting the Battery
! | Connect negative (−) |
| cable last.− |
| + |
Tools Needed: |
|
1/2 in |
|
| Ref. 226 |
|