5. Specifications

Display

5 Digit LCD with bar graph indicator

Unit of Measurement

Humidity: %RH (Relative Humidity)

 

 

 

 

Temperature: °C or °F

 

Dew Point: °C or °F

Temperature Compensation

Automatic for humidity function

Sampling Time of Data Logger

Manual

Pushing the data logger button once will

 

 

save data one time

 

 

 

 

Auto

1, 2, 10, 30, 60, 600, 1800, 3600 seconds

Humidity / Temper atur e

 

 

 

Range

0% to 95% RH

Humidity

Resolution

0.01% RH

Accuracy

>70%RH +(3% rdg. + 1% RH)

 

 

 

<70%RH - 3%RH +3%RH

 

 

 

 

Range

32°F to 122°F, (0°C to 50°C)

Temperature

Resolution

0.01 degree

 

Accuracy

°C = + 0.8°C / °F= + 1.5°F

Dew Point

 

 

°C

Range

-25.3°C to 48.9°C

Resolution

0.01°C

 

°F

Range

-13.5°F to 120.1°F

Resolution

0.01°F

 

Dew Point

Accuracy

sum of RH and Temperature accuracies

 

 

Data Hold

Display freeze

Memory

Saves MAX. or MIN values with recall

Sampling Time

Approx imately 0.8 seconds

Power Off

Auto or manual control

Data Output

RS-232 Serial data output

Operating Environment

32° to 122°F (0° to 50°C), <85% R.H.

Power Supply

6 Pieces of DC 1.5V Batteries (UM4, AAA or equivalent)

Weight (approx .)

0.74lbs. (336g)

Dimensions (approx .)

Main instrument: 6.9 x 2.7 x 1.7" (174 x 68 x 42mm)

 

Sensor probe length: 7.8" (197mm)

Included Accessories

Instruction manual, battery, carrying case

*= Note : Accuracy applicable in environments with RFI <3V/M with Hz <30MHz, and temperatures between 20°C to 26°C

Specifications and information are subject to change without notice

Please visit www.anaheimscientific.com for the most current product information.

5

Image 6
Contents Humidity/Temp Meter With DEW Point and Data Logger Page Advanced Measuring Procedures ……………………… Auto Power Off Disable ……………………………………Send Data fr om RS232 Socket …………..………………… Product Introduction Features ApplicationsSafety Inform ation Safety Sym bolsSpecifications Humidity / Temper atur eDew Point Unit Diagram Operation InstructionsDEW Point Measurem ent Measuring ProcedureHumidity & Tem perature Measurem ent Data HoldManual Data Logger set sample time to 0 seconds Change Data Logger Sampling Tim e Advanced Measuring ProceduresChange Unit of Measure from C to F Show Memory BalanceAuto Power Off Disable Clear Mem oryRS232 PC Serial Interface Inform ation Send Data fr om RS232 SocketBattery Replacem ent RS232 SettingEach digit indicates the following status Service Inform ation Lim ited Tw o-Year Warranty Anaheim Scientific