FRONT PANEL AOJUSTMENTS
Touch Key
1 Index: Allows the following adjustments to be selected.
| 1) Set point temperature | ||
| 
 | 
 | |
| 2) | Heat cycle time | *1 to 120 seconds | 
| 3) | Prop. Band (indicated | |
| 
 | as gain) | |
| 4) Rate with tracking reset | ||
| 5) | Auto Tune (AT) | 
 | 
Up/Down keys: increases/decreases values of above adjustments.
Tune/Cancel: "cancel" puts output on 
"tune" triggers automatic tuning procedure
E Enter: writes selected value to nonvolatile memory
NOTES: *setting to zero initiates 60 millisecond timebase for ultra fast cycling. Use with external solid state relays or SCR Power Controllers.
**Setting to zero disables reset and rate action for proportional only control. Reset is six times higher than rate
FOR OPTIMUM RESULTS WITH THE AUTO-TUNE  MODEL 6050
1.Set point must be a minimum of 100°F above ambient for proper 
2.
4