Sanyo Understanding Your Micro Computer Air Conditioner: Operation and Fan Speed Control

Page 13

Operation with the Remote Control Unit (continued)

NOTE

2.Adjusting the Fan Speed

A.Automatic

Cooling and DRY mode:

B. Manual

·This appliance has a built-in three minutes time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. When the power is restored, the unit will restart automatically after five minutes.

Simply set the FAN SPEED selector button to the position.

A microcomputer in the air conditioner automatically controls the fan speed

when the mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level.

When difference between

 

room temperature and set

FAN SPEED

temperature is

 

 

 

4 °F and over

High

 

 

Between 4 °F and 2 °F

Medium

 

 

Below 2 °F

Low

 

 

If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired. [ , , or ]

OI-330-13EG

13

Image 13
Contents KS0951 KS1251 KS1852 Features Alert Symbols ContentsProduct Information Safety Instructions Installation LocationElectrical Requirements Indoor Unit Names of PartsOutdoor Unit Timer lamp Operation lamp Remote control receiver Remote control receiverOFF position does not disconnect the power. Use the main Power switch to turn off power completelySET Temp Button Timer on button Temperature settingTimer OFF button TransmitterDRY Remote Control UnitCool How to Install Batteries Using the Remote Control UnitHow to Use the Remote Control Unit Remote Control Unit Installation PositionMounting the Remote Control Unit Using the Remote Control UnitManual Operation Operation with the Remote Control UnitStep Adjusting the Fan Speed Operation with the Remote Control UnitFAN Speed Night Setback Mode is used for saving energy Night Setback ModeSetting Temperature 30 min Press Time Cooling and DRYRemote Control Unit Power failure during operation Clicking SoundSpecial Remarks ``DRY OperationTimer on mode Example Using the 12-Hour on and OFF TimerTimer OFF mode Example Setting procedureHour OFF Timer Using the 1-Hour OFF TimerCombining the 1-Hour OFF Timer and 12-Hour on Timer Setting the airflow manually Adjusting the Airflow DirectionHorizontal Vertical Sweep DRY Recommended operating range Sweep functionCare and Cleaning Operation without the Remote Control UnitCasing and Grille Indoor Unit Anti-mold filter How to remove the anti-mold filter Care and CleaningHow to replace the anti-mold filter Air intake grilleKS0951/KS1251 Air cleaning filter not providedDo not · Tips for Energy SavingDo · Removing and remountingOperating Range TroubleshootingTrouble Possible Cause Remedy Sanyo Fisher Company CanadaSanyo Canada Inc Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 9.78 Kb

KS1852, KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.