Sanyo KS1852, KS0951, KS1251 Night Setback Mode is used for saving energy, Cooling and DRY

Page 14

Operation with the Remote Control Unit (continued)

3. Night Setback Mode

SET TEMP.

NORMAL

1HR.

ON

 

TIMER

OFF

TEMP.

FLAP FAN SPEED MODE

ON OFF

NIGHT

SET CANCEL SETBACK

BATTERIES ACL

The Night Setback Mode is used for saving energy.

Press the NIGHT SETBACK button while the air conditioner is operating.

The mark appears in the display.

To cancel the night setback function, press the NIGHT SETBACK button again.

In Cooling and DRY

Mode: When the night setback mode is selected, the air conditioner

( and ) automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

 

 

 

 

2 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

 

2 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

 

 

30 min.

 

 

 

Time

 

NIGHT SETBACK

 

 

 

button

14

OI-330-14EG

Image 14
Contents KS0951 KS1251 KS1852 Features Product Information ContentsAlert Symbols Electrical Requirements Installation LocationSafety Instructions Outdoor Unit Names of PartsIndoor Unit OFF position does not disconnect the power. Use the main Remote control receiverTimer lamp Operation lamp Remote control receiver Power switch to turn off power completelySET Temp Timer OFF button Temperature settingButton Timer on button TransmitterCool Remote Control UnitDRY How to Use the Remote Control Unit Using the Remote Control UnitHow to Install Batteries Remote Control Unit Installation PositionUsing the Remote Control Unit Mounting the Remote Control UnitStep Operation with the Remote Control UnitManual Operation FAN Speed Operation with the Remote Control UnitAdjusting the Fan Speed Setting Temperature 30 min Press Time Night Setback ModeNight Setback Mode is used for saving energy Cooling and DRYSpecial Remarks Power failure during operation Clicking SoundRemote Control Unit ``DRY OperationTimer OFF mode Example Using the 12-Hour on and OFF TimerTimer on mode Example Setting procedureCombining the 1-Hour OFF Timer and 12-Hour on Timer Using the 1-Hour OFF TimerHour OFF Timer Horizontal Vertical Adjusting the Airflow DirectionSetting the airflow manually Sweep DRY Recommended operating range Sweep functionCasing and Grille Indoor Unit Operation without the Remote Control UnitCare and Cleaning How to replace the anti-mold filter Care and CleaningAnti-mold filter How to remove the anti-mold filter Air intake grilleAir cleaning filter not provided KS0951/KS1251Do · Tips for Energy SavingDo not · Removing and remountingTrouble Possible Cause Remedy TroubleshootingOperating Range Sanyo Canada Inc CanadaSanyo Fisher Company Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 9.78 Kb

KS1852, KS1251, KS0951 specifications

The Sanyo KS0951 and KS1251 are two formidable air conditioning units designed to deliver optimal cooling performance while ensuring energy efficiency. Sanyo, renowned for its innovative technologies, has incorporated a range of advanced features into these models, making them suitable for both residential and commercial applications.

One of the key features of the Sanyo KS0951 and KS1251 is their high energy efficiency rating. Both models utilize advanced inverter technology, which allows the units to adjust their compressor speed according to the cooling demands. This variable speed operation not only provides consistent temperature control but also reduces energy consumption significantly, leading to lower electricity bills.

The cooling capacity of the KS0951 is approximately 9000 BTUs, while the KS1251 boasts a capacity of around 12000 BTUs. This makes them ideal for medium-sized to larger rooms, offering effective cooling even in hot weather conditions. With efficient airflow distribution, these units ensure that every corner of the room receives adequate cooling.

Another notable characteristic of the Sanyo KS series is the implementation of advanced air filtration systems. Equipped with multi-stage filters, these units effectively remove dust, allergens, and other airborne particles, promoting a healthier indoor environment. The filters are easy to access and clean, ensuring that maintenance is hassle-free and air quality remains high.

Noise reduction technology is another significant feature of the KS0951 and KS1251. Both models operate at low noise levels, providing a peaceful environment, whether it’s at home or in an office setting. This acoustic comfort is further enhanced by the use of sound-dampening materials and advanced compressor designs.

User-friendly features also set these models apart. The inclusion of remote control functionality allows users to adjust settings conveniently from anywhere in the room. Additionally, programmable timers and multiple cooling modes provide flexibility according to various needs and preferences.

In conclusion, the Sanyo KS0951 and KS1251 are standout air conditioning units that combine efficient cooling performance with user-friendly features and advanced technology. Their ability to provide a comfortable and healthy indoor environment, coupled with energy efficiency, makes them a wise choice for consumers seeking reliability and innovation in climate control solutions. Whether for home or office use, these models exemplify Sanyo's commitment to quality and customer satisfaction.