Repair
Repair
Replace the Throat Packings
Without Disconnecting the
Lower
NOTE: Throat packing kits are available. See page 22. Kit parts are marked with a symbol, for example (30†). For best results, install the TSL Pump Repair Kit 24F618 each time the throat packings are changed.
NOTE: To replace the throat packings as part of a com- plete service of the lower, see page 9.
NOTE: Tool Kit 24F494 is available as an accessory. The kit includes two wrenches for use with the
1.Flush the pump, if possible.
2.Stop the pump at the middle of its stroke.
3.Relieve the pressure. See your separate pump manual.
4.Following the instructions in your separate pump manual, remove the
5.See FIG. 5. Remove the collar (41) and screws (56), cap (40), and manifold and bottle assembly (53).
6.Remove the
7.Remove the throat cartridge (27). Remove the
NOTE: Inspect the surface of the piston rod (19). If it is scratched, replace the piston rod.
8.Lubricate the throat packings and glands. Install the spring (28) and one male gland (31†) in the throat cartridge (27), then seven
9.Lubricate the
10.Install the
11.Torque the cartridge (27) to
12.Torque the
13.Reassemble the spring (35), TSL pump piston seal (36), and
14.Reassemble the manifold and bottle assembly (53), cap (40), collar (41) and screws (56). Torque the cap (40) to
15.Reinstall the coupling nut and collars on the piston rod (19).
16.Reconnect the coupling nut to the motor shaft. See your separate pump assembly manual for correct torque specifications for your model. Reinstall the shield.
3A0540L | 7 |