Issue:

Wiring Fault LED is illuminated.

Possible Cause:

AC Mains outlet is wired incorrectly.

Action Needed:

Contact a certified electrician to inspect the building's wiring.

Issue:

No power to the AC outlets.

Possible Cause:

Circuit breaker has tripped due to excessive load.

Action Needed:

Remove one piece of equipment from the ETA-C15D, and push the breaker reset tab located on the

 

front panel. Note: We suggest first locating the highest power-consumer such as a power amplifier and

 

disconnecting or turning down that unit. If the ETA-C15D breaker continues to trip, relocating some of the gear

 

may be required.

Issue:

No power to the AC outlets, “Abnormal Voltage” indicator is illuminated, the Volt Meter is Flashing and you

 

hear a buzzer from the unit.

Possible Cause:

The AC Mains Voltage exceeded 132VAC or the voltage dropped below 101VAC

Action Needed:

Measure the AC mains before the ETA-C15D. If the voltage is between 117VAC and 123VAC you may proceed

 

to reset the ETA-C15D by restarting the start up sequence.

 

Note: It is important to have all equipment that was connected to that AC Mains Line to be inspected for

 

proper operation. If the problem persists, contact your local power company for the cause of unstable AC line

 

conditions.

Issue:

Abnormal LED Flashing and you have power to all outlets.

Possible Cause:

The AC Mains Voltage exceeded 128VAC or the voltage dropped below 107VAC

Action Needed:

The ETA-C15D must be reset to turn off the LED. Measure the AC mains before the ETA-C15D. If the voltage

 

is between 117VAC and 123VAC you may proceed to reset the AP-C15D by cycling the Power Switch

 

Off / On. Note: It is important to have all equipment that was connected to that AC Mains Line inspected for

 

proper operation. If the problem persists, contact your local power company for the cause of unstable AC line

 

conditions.

Issue:

AC Fault LED is Flashing, a buzzer is sounding and you have no power at any outlets.

Possible Cause:

Although the Dual Clamping Suppression (DCS) circuit virtually assures protection from most transient voltage

 

spikes and surges, nature has a way of occasionally creating electrical forces that are beyond the capabilities

 

of any device to absorb without some degree of damage. In the rare instance that this occurs, the DCS circuit

 

has been damaged during the suppression.

Action Needed:

If this happens, the ETA-C15D will shut off and the unit will need to be repaired or replaced. It is important to

 

have all equipment that was connected to that AC Mains Line inspected for proper operation.

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

– 10 –

ETAsys.com

Specifications are subject to change without notice.

Image 10
Contents ETA-C15D Table of Contents Important Safety Instructions ETA-C15D Introduction Front Panel Features KEY FeaturesApplications 10 11 Rear Panel Features InstallationAC Power Cord Retainer System Troubleshooting Guide To reset the ETA-C15D by restarting the start up sequenceETA-C15D Specifications Technical DataLimited Warranty Service

ETA C15D specifications

The ETA Systems ETA C15D is a cutting-edge power management solution designed for both residential and commercial applications. Its primary objective is to provide efficient energy use while ensuring system reliability and flexibility. This compact unit integrates advanced technologies to manage energy distribution intelligently and sustainably.

One of the standout features of the ETA C15D is its ability to monitor and control energy consumption in real time. The system employs a sophisticated energy management software that allows users to track energy usage patterns, identify peak consumption times, and receive alerts for unusual energy spikes. This capability not only aids in reducing overall energy costs but also contributes to lowering the carbon footprint of the property.

The ETA C15D incorporates smart grid technology, making it capable of communicating with other energy systems. This integration is crucial for optimizing energy flow from renewable sources, such as solar panels and wind turbines. By leveraging smart grid features, the ETA C15D can balance energy loads efficiently, ensuring sustainability and maximizing the use of clean energy sources.

Additionally, the ETA C15D features multiple power output options, catering to various appliances and electronic devices. Users can manage different devices on separate circuits, providing precise control over energy distribution. This flexibility is particularly beneficial in commercial setups where energy demand may fluctuate significantly throughout the day.

Security is another important aspect of the ETA C15D. The system includes built-in protection features that safeguard against surges, overloads, and short circuits. This protective technology ensures the longevity of connected devices and enhances overall system reliability.

User experience is also prioritized in the design of the ETA C15D. Its interface is user-friendly and accessible, allowing for easy installation and configuration. The accompanying mobile application enables users to monitor their energy consumption remotely, providing insights and controls at their fingertips.

In summary, the ETA Systems ETA C15D stands out as a versatile and intelligent energy management solution. With its innovative technologies, user-centric design, and commitment to sustainability, it represents a significant step forward in modern power management systems. Whether for a home or business, the ETA C15D offers the features necessary to optimize energy use effectively while promoting an eco-friendly approach.