Graco Inc 1204E, 800-051, 801-238 manual High Pressure Spray can Cause Serious Injury, 412681-6669

Page 2

HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY.

FOR PROFESSIONAL USE ONLY.

OBSERVE ALL WARNINGS .

Read and understand all instruction manuals before operating equipment .

INJECTlON

 

 

FIRE

~. ~..

.

.. .

,..

, . .",.

 

;~..._il_x_~**"~.

 

 

:..

.~,

 

 

 

, . ,,,: , >,...i ~~i.-:.*<,.'. .,.,-.'i,*...,.,,,,,*+.._c.

fluids under high pressure from spray or leaks can

Do not spray flammable liquids. Do not operate the unit

penetrate the skin and cause extremely serious injury,

where combustible fumes or dust may be present.

 

 

including the need for amputation.

 

GENERAL

 

'.

 

 

 

.

.. - , .

., .. ,,..,I

,.. , . .1. ~~

. .> ..

.:

,

NNER point the spray gun at anyone or any part ofthe

'

 

 

 

 

,,

.:,

:k;k'

,,.!$.,,>~.

:.

 

NNER run the unit withthe belt guard removed. Keep

body.

 

 

NNER put hand or fingers over the spray tip.

clear of moving parts whenthe unit is running.

 

 

 

Observe detergent manufacturer's safety precautions.

 

 

 

NNER try to stop or deflect leaks with your hand or

Avoid getting detergent or other liquids in your eyes.

body.

 

 

Follow the

directions the

 

container

regardingcontact

 

 

 

with eyes, nose, and skin, breathingfumes, etc. Always

ALWAYS have the tip guard in place when spraying.

wear full goggles to protect

youreyes from the spray as

M E D I C A L TREATMENT&~;T:",'? ''<?.X

 

well as any debris dislodged by thespray. If necessary,

 

wear gloves or other protective clothing. If antidotesor

If any fluid appears to penetrate your skin, get

treatment are recommended, be prepared to use them.

DON'T spray toxic chemicals such as insecticide or

EMERGENCY MEDICAL

CARE AT ONCE.

BO NOT TREAT AS A S!MPLE

CUT.

weed killer.

 

 

 

 

 

 

 

 

 

 

 

 

 

Tell thedoctorexactlvwhatfluld

was

miected. For

This unit has a 3-prong grounding plug to protect you

treatment instructionshave your doctor Cali the

NATIONAL POISON CENTER NETWORK

from electric shock. Be sure to plug the unit intoa pro-

(412)681-6669

 

perly grounded outlet

that

 

willaccept the 3-prong

plug.

A V O I D C O M P O N E N T RUPTURE"~~,-:r_',":;i.'.

Do not remove the thirdprong.

 

 

 

 

 

 

The green wire of the electric cord is connected to the

Even after you shutoff the electric motor, there is high

unit chassis and motor frame and the other two wires

pressure in the pump, hose and gun untilyou relieve it

are connected

tothemotorswitchfor

 

 

grounding

by triggering thegun. So before removing thespray tip

continuity.

 

 

 

 

 

 

 

 

 

 

 

 

 

or servicing theunit, a h y s shut off the unit andtrigger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the gun to release pressure.

 

 

The electric motor hasan

 

overloadprotection device

Be sure that all accessory items and system com-

which automatically shuts off the motor ifit overheats.

So, before examining or working on a motor which has

ponents will withstand thepressure developed. NNER

stopped, shut off the unit, relieve pressure and pull out

.exceed the pressure rating ofany component in system.

the electrical plug. This will avoidthe

hazard of the

NNER alter or modifyequipment-your

personal

motor startingunexpectedly.

 

 

 

 

 

 

 

safety, as well as the function of the equipment, is at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stake.

 

 

ALWAYS CHECK to besure theswitch is OFF and that

Before each use, check hose for weak, worn or damag-

the hoses and electric cord are clear of moving parts

before plugging in the power cord.

 

 

 

 

 

 

ed conditions caused by traffic, sharp corners, pinching or kinking. Tightenall fluid connections securely before each use. Replace any damaged hose.

Do not use chemicals or agents which are not compati- ble with Buna-N and PVC or neoprene cover of hose.

Do not leave a pressurizedunit unattended. Shutoff the unit and relieve pressure before leaving.

IMPORTANT

United StatesGovernment safety standards have been adopted under the Occupational Safety and Health Act. These standards - particularly the GeneralStandards, Part 1910, and the Construction Standards, Part 1926 - should be consulted in connection with your use of airless spray equipment.

2 , 801-238

."

Image 2
Contents Model 8OO-051 Series B High Pressure Spray can Cause Serious Injury 412681-6669Operation StartupAccessories Shutdown and Care of UnitDischarge Valves & Valve Seats Pumping Section BE2Pumping Section Cutaway Diagnosis and MaintenanceProbable Cause Solution Lug Lhort cup life~ l u a0-Ring Problem IrunParts Drawing ServiceGun andHose Assembly 800-017T91Ts Valve kit Parts Drawing Parts List801-108 Chemical Injector KIT Technical DataLimited Warranty Prevents back up of contaminated water into fresh

1204E, 801-238, 800-051 specifications

Graco Inc. is a globally recognized brand in fluid handling, offering a diverse range of products characterized by durability, efficiency, and innovative technology. Among its extensive product line, the Graco Inc. models 1204E, 801-238, and 800-051 stand out due to their unique features and robust design, making them essential tools in various industrial applications.

The Graco Inc. 1204E is an advanced air-operated double diaphragm pump known for its exceptional performance and reliability. This model is built with high-quality materials that ensure longevity even in demanding environments. One of its main features is the ability to handle a wide range of fluids, including thick and abrasive materials. The 1204E utilizes a control system that maximizes efficiency by adjusting flow rates automatically, leading to reduced operational costs and improved productivity. Furthermore, its compact design allows for easy installation in tight spaces, making it a versatile choice for numerous applications.

The 801-238 model is a high-performance grease pump specifically designed for reliable lubrication. This pump is equipped with a user-friendly interface and a powerful motor that contributes to its impressive output capabilities. Its robust construction allows it to withstand harsh conditions, ensuring that maintenance tasks can be performed with minimal downtime. A standout feature of the 801-238 is its integrated monitoring system, which provides real-time feedback on pump performance, helping operators to ensure optimal efficiency and identify potential issues before they escalate.

Lastly, the 800-051 represents Graco's commitment to precision and reliability in paint application. This model is engineered to deliver a consistent spray pattern, allowing for a flawless finish every time. The 800-051 incorporates advanced technology that minimizes overspray and waste, making it both an economical and environmentally friendly option. Additionally, its ergonomic design ensures ease of use, which is especially beneficial for long hours of operation.

In conclusion, the Graco Inc. models 1204E, 801-238, and 800-051 highlight the company's dedication to innovation and quality. Each model features technologies that enhance usability and efficiency, ensuring they meet the diverse needs of their users in industrial settings. With Graco's reputation for excellence, these products continue to set the standard in their respective fields.