Graco Inc 800-700, 800-699 manual Equipment Misuse Hazard, Hose Safety, Fuel and Emission Hazards

Page 4

EQUIPMENT MISUSE HAZARD

General Safety

Any misuse of the pressure washer or accessories, such as overpressurizing, modifying parts, using incompatible chemicals and fluids, or using worn or damaged parts, can cause them to rupture and result in fluid injection, splashing in the eyes or on the skin, or other serious bodily injury, fire, explosion or property damage.

NEVER alter or modify any part of this equipment; doing so could cause it to malfunction.

CHECK all spray equipment regularly and repair or replace worn or damaged parts immediately.

ALWAYS wear protective eyewear and appropriate clothing. If using a chemical injector, read and follow the chemical manufacturer’s literature for recommendations on additional protective equipment, such as a respirator.

HOSE SAFETY

High pressure fluid in the hoses can be very dangerous. If the hose develops a leak, split or rupture due to any kind of wear, damage or misuse, the high pressure spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage.

ALL FLUID HOSES MUST HA VE STRAIN RELIEFS ON BOTH ENDS. The strain reliefs help protect the hose from kinks or bends at or close to the coupling, which can result in hose rupture.

TIGHTEN all fluid connections securely before each use. High pressure fluid can dislodge a loose coupling or allow high pressure spray to be emitted from the coupling.

FUEL AND EMISSION HAZARDS

NEVER fill the fuel tank while the unit is running or hot. The fuel used in this unit is combustible and when spilled on a hot surface can ignite and cause a fire. ALWAYS fill tank slowly to avoid spilling.

NEVER operate the unit in a closed building. The exhaust contains carbon monoxide, a poisonous, odorless,

System Pressure

This sprayer can develop high operating pressures. Be sure that all spray equipment and accessories are rated to withstand the maximum working pressure of this

sprayer. DO NOT exceed the maximum

working

pressure of any component or accessory used in the system.

Chemical Compatibility

BE SURE that all chemicals used in the chemical injector are compatible with the wetted parts of the hose, gun, wand and tip, as given in the Technical Data (inside back

cover). Always read the chemical manufacturer

’s

literature before using any chemical in this pressure

 

washer.

 

NEVER use a damaged hose. Before each use, check entire hose for cuts, leaks, abrasion, bulging cover , or damage or movement of the hose couplings. If any of these conditions exist, replace the hose immediately. DO NOT try to recouple high pressure hose or mend it with tape or any other device. A repaired hose cannot contain the high pressure fluid.

HANDLE AND ROUTE HOSES CAREFULL Y. Do not pull on hoses to move the pressure washer. Do not use chemicals which are not compatible with the inner tube and cover of the hose. DO NOT expose Graco hose to temperatures above 200_￿F (93_￿C) or below –40_F (–40_￿C).

invisible gas which can cause serious injury or death if inhaled.

NEVER alter the throttle setting, which is factory set. Tampering with this adjustment can damage the pressure washer and will void the warranty.

IMPORTANT

United States Government safety standards have been adopted under the Occupational Safety and Health Act. These standards—particularly the General Standards, Part 1910, and the Construction Standards, Part 1926—should be consulted.

4308–530

Image 4
Contents 1535 2040 2540 Rev a 800-698, Series a 800-699, Series aIndex TermsGeneral Safety Pressure Relief ProcedureSpray Gun Safety Devices Moving Parts HazardHose Safety Equipment Misuse HazardFuel and Emission Hazards System PressureInstallation Set Up1535 Check for Shipping DamageStartup Installing and Changing Spray Tips Trigger Safety LatchFollow the Pressure Relief Procedure Maintenance Pressure Relief ProcedureSHUTDOWN, Flushing Storage Interval What to doTroubleshooting Chart ProblemHydra-Cleanr1535 Pressure Washer Parts DrawingParts List Part Description QTYHydra-Cleanr2040 Pressure Washer WASHER, Flat 3/8 804-249 Assembly incl 802-139 Hydra-Cleanr2540 Pressure Washer FILTER/STRAINER Gear Reducer Service Model Replacing the O-RingReplacing the Gasket Replacing the Oil SealGear Reducer Model BearingGear Reducer Service Models 2040 Replacing the Oil SealsGear Reducer Models 2040 Pump Assembly, 1500 psi Kit Repair Kit Description Qty 804-102 804-101Pump Assembly, 2000 psi Kit Repair Kit Description Qty 804-100 804-096Pump Assembly, 2500 psi Kit Repair Kit Description Qty 804-098 804-234 STUD, Retaining 6mm x 64,5mm804-097 Servicing the Valves Pump Service ModelServicing the Seals Reassembly Torque Chart Pump Part Thread Tool SizeServicing the Plungers Servicing Crankcase SectionPump Service Models 2040 308-530 ReassemblyServicing the Pumping Section Servicing the Seals and V-PackingsReassembly Packing ModelsHigh Pressure Seal Models Low Pressure Seal-All ModelsAccessories Downstream Chemical Injector KIT 800-117Technical Data ModelImportant Phone Numbers Graco WarrantyGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN