Tighten drain plug again

Slowly fill with oil as far as MAX mark Air bubbles must be able to escape

Refer to technical data for oil grade and quantity to be used.

FAULTS

The indicator lamp- MOTOR/ELECTRONICS MODULE (item 28) flashes

(only HDS 995 and HDS 1295)

*This warning lamp flashes if there is a problem.

*When you open the cover (item 8) of the compartment (item 6) the electronic display is visible in the window (item 4).

*The warning lamp goes out when the problem has been resolved and the unit is switched on again.

Display

Troubleshooting

Increase the water inlet volume

Clean strainer in water connection

Clean the strainer (coarse) fitted in front of the low water protection

Display

Troubleshooting

Replace the reed switch for the low water protection *

Clean the low water protection *

Display

Troubleshooting

Eliminate the leakage in the high-pressure system

Display

Troubleshooting

Motor is overloaded/overheated

Set the monitoring switch to "0" and allow the motor to cool off for at least 5 min

Have unit checked by After-Sales Service if this does not remedy fault

Display

Troubleshooting

This error code appears only on units equipped with the – accessory kit flame monitoring system -

See the assembly instructions – accessory kit flame monitoring system -

*This maintenance work should be performed only by after-sales service.

The READY FOR WORKING indicator lamp (item 28) goes out

(HDS 745, HDS 695 S, HDS 895 S, HDS 1195, HDS Super)

Motor overloaded/overheated

Set selector switch to "0" and allow motor to cool down for at least 5 min.

Have unit checked by After-Sales Service if this does not remedy fault.

No mains voltage (see – unit does not run -)

The FUEL indicator lamp (item 25) is lit (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Fuel tank empty

Fill up

The READY FOR WORKING indicator lamp (item 29) goes out

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Engine is overloaded

Set selector switch to "0" and allow motor to cool down for at least 5 min.

Have unit checked by After-Sales Service if this does not remedy fault.

No mains voltage (see – unit does not run -)

SCALE INHIBITOR indicator lamp (item 26) is lit

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Scale inhibitor reservoir empty; for technical reasons there is always a residual quantity in the reservoir.

Fill up

Dirt on electrodes in reservoir

Clean electrodes

Image 11
Contents HDS Super HDS 695 S HDS 745 HDS 895 S HDS 995 HDS 1195 HDS Page Page Environmental Protection ContentsControl Elements Illustration of the UnitCommissioning Operation Intended use Measuring out the cleaning agentCleaning Recommended cleaning method Loosen up dirtDiscontinuation of Usage MaintenanceEach Time After Usage Reading the Operating HoursMaintenance Tasks Display Troubleshooting FaultsNo mains voltage Check mains connection/power cord General Instructions WarrantyWater connection Technical DataType HDS 995 HDS 1195 HDS 1295 Mains connection Page EU Declaration of Conformity