Unit does not run

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

No mains voltage

Check mains connection/power cord

Unit does not build up pressure

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Air in system

Bleed pump:

*Set the cleaning agent metering valve (item 31) to "0"

*While the handgun is open switch the unit on and off several times with the unit switch.

*With handgun open, open and close regulator (Figure 9).

*Venting is accelerated by removing the high-

pressure hose from the high-pressure connection.

Fill up cleaning-agent tank if empty.

Check connections and lines

Pressure set to MIN

Set pressure to MAX

Strainer in water connection dirty

Clean strainer Insufficient water supply

Check water supply volume (refer to technical data)

Unit leaking, water dripping out at bottom (HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Pump leaking

3 droplets/min are permitted.

In the event of a major leak, have unit checked by After-Sales Service.

Unit constantly switched on and off with handgun closed

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Leak in high-pressure system

Check high-pressure system and connections for leaks

Unit does not draw in cleaning agent

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Operate the unit with an opened cleaning agent metering valve and a shut off water inlet until

the float tank is suctioned empty and the pressure drops to "0".

Now reopen the water inlet.

If the pump still does not suction up cleaning agent the reasons can be as follows:

Filter in cleaning-agent suction hose dirty

Clean filter

Non-return valve gummed up

Pull the cleaning agent hose off and detach the non-return valve with a blunt object, see Figure 15.

Burner not ignited

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Fuel tank empty

Fill up

Lack of water

Check water connection, check supply lines, clean low water protection.

Fuel filter dirty

Replace fuel filter.

Incorrect direction of rotation. If direction of rotation is correct, powerful jet of air will be felt at exhaust-gas opening of burner.

Check direction of rotation. If

necessary change the poles at the unit plug. See figure 16.

No ignition spark

Have unit checked by After-Sales Service if no ignition spark is visible through inspection glass during operation.

Set temperature not attained when working with hot water

(HDS 745, HDS 695 S, HDS 895 S, HDS 995, HDS 1195, HDS 1295, HDS Super)

Excessive operating pressure/flow rate

Reduce operating pressure/flow rate by way of regulator (Figure 9)

Soot deposits on heating coil

Have After-Sales Service remove soot deposits from unit

If the problem cannot be resolved the unit must be checked by after sales service.

Image 12
Contents HDS Super HDS 695 S HDS 745 HDS 895 S HDS 995 HDS 1195 HDS Page Page Contents Environmental ProtectionIllustration of the Unit Control ElementsCommissioning Operation Measuring out the cleaning agent CleaningRecommended cleaning method Loosen up dirt Intended useMaintenance Each Time After UsageReading the Operating Hours Discontinuation of UsageMaintenance Tasks Faults Display TroubleshootingNo mains voltage Check mains connection/power cord Warranty General InstructionsTechnical Data Water connectionType HDS 995 HDS 1195 HDS 1295 Mains connection Page EU Declaration of Conformity