Operation
Installing and Changing Spray Tips
WARNING
To reduce risk of serious bodily injury, including fluid injection or splashing in eyes or onto skin, use extreme caution when changing spray tips. always follow procedure below.
1.Follow the Pressure Relief Procedure.
2.Point the gun and wand away from yourself and anyone else.
3.Without holding your hand over the spray tip (A), pull back the quick coupler ring (B). Remove the old tip and/or install a new one, and then release the ring. See Figure 3.
4.Be sure the tip is secure before starting to spray again.
5.Tip holding holes are provided on the chassis.
CAUTION |
|
To avoid blowing |
|
high pressure in system, never operate pressure |
|
washer without tip securely mounted in quick |
|
coupler. | 04929 |
B
A
Figure 3
8308532