DE-SOOTING COIL

Poor grades of fuel oil or inadequate combustion air will cause heavy soot build up on the outside surface of the heating coil. This will insulate the coil and restrict air flow through the coil, further aggravating the soot build up.

To clean off soot, add Red Devil Soot Remover, using manufactures mixing instructions, or remove coil and clean thoroughly, or Call a Factory Authorized DELCO Dealer.

DE-LIMING OR DE-SCALING OF COIL

In hard water areas, or when using the wrong kind of soap, lime build-up inside the coil pipe will occur. Lime build-up will decrease the water temperature, water flow may eventually plug the coil.

It is recommended that a low pressure auxiliary pump be used if de-liming or de-scaling is needed. To install low pressure auxiliary pump.

1.Disconnect high pressure hose that goes between high pressure pump and coil inlet.

2.Connect about four feet of hose with screen to suction side of a low pressure auxiliary pump.

3.Connect a discharge hose between the low pressure auxiliary pump discharge side and the inlet.

4.Disconnect high pressure discharge hose from coil outlet.

5.Connect another 5-6 feet of hose to the coil outlet and run to a 5 gallon bucket.

6.Stick low pressure auxiliary pump suction hose w/screen into 5 gallon bucket.

7.Mix 2 gallons of water with 1 container of Coil Doctor.

8.Turn on pump and circulate the acid mixture through the coil system for about 40 minutes or until discharge solution stops foaming.

After cleaning, remove low pressure auxiliary pump assembly and connect all plumbing. Remove pressure tip from end of wand. Turn on pressure washer and run clean water through machine for about 5 minutes. This flushes out the coil and neutralizes any remaining acid. Replace pressure tip.

OR, call your Factory Authorized DELCO® Distributor.

WARNING :

COIL DOCTOR IS ACID AND IS HARMFUL TO SKIN AND EYES.

ALWAYS FOLLOW MANUFACTURERS LABEL DIRECTIONS.

Manual

Page 11

Image 11
Contents King Brute Limited Warranty Limited Warranty DO’S Important Safety PrecautionsHOT Venting the Units InstallationLocation Fuel SupplyOperating Instructions Operating the MachinePRE-OPERATING Instructions Things to Check Weekly Shut Down InstructionsThings to Check Daily OIL Burners Maintenance of ComponentsPumps Winterizing DE-LIMING or DE-SCALING of Coil DE-SOOTING CoilProblem Probable Cause Solution Diagnosis and MaintenanceManual PUM0015 PPA0015 Unloader Burner Beckett 12V Component Locator & Parts List Electrical Schematic 12VDC Gunvalve and Hose Assembly Component Locator Gunvalve and Hose Assembly Component Locator Parts List GC 590-40 Gunvalve Component Locator GC 590-40 Gunvalve Component Locator Parts List