SHUT DOWN INSTRUCTIONS
1.If the burner is on turn control switch to position 1(pump).
2.Run water through the pump until cool water flows from the cleaning gun. Failure to do this could result in increased coil scaling.
3.Turn the control switch to off.
4.Turn off the water supply.
5.If the machine will be exposed to freezing temperatures, see winterizing procedure.
THINGS TO CHECK DAILY
1.Check oil level in pump.
2.Fill fuel tank at the end of each day’s use to prevent condensation
3.Fill soap container.
4.Check oil level in engine.
THINGS TO CHECK WEEKLY
1.Check and clean water float tank and pump inlet screen.
2.Check all hoses for leaks and damage. Repair or replace as needed.
3.Check pressure nozzle for wear. Replace if needed.
4.Check all nuts and bolts. Tighten as needed (DO NOT OVER TIGHTEN.)
5.Check all water connections for leaks. Tighten if loose.
6.Check belts and pulleys for wear and tightness. (DO NOT CHECK WHILE MACHINE IS RUNNING.)