Taylor Pool Heat Pump owner manual Error Code List

Page 22

ERROR CODE LIST

CODE

SYMPTOM

PROBABLE CAUSE

SOLUTION

 

 

 

 

 

Open-Circuit in evaporator

 

Reset the heat pump from the

DSO

temperature sensor

The evaporator temperature sensor

breaker

 

 

is incorrectly plugged in or defective

 

 

Heat pump stopped

 

Call an authorized technician

 

 

 

 

 

Open-Circuit in water

 

Reset the heat pump from the

SO

temperature sensor

The water temperature sensor is

breaker

 

incorrectly plugged or defective

 

 

 

 

 

Heat pump stopped

 

Call an authorized technician

 

 

 

 

 

Short circuit in evaporator

 

Reset the heat pump from the

DSc

temperature sensor

The evaporator temperature sensor

breaker

 

is incorrectly plugged in or defective

 

 

 

 

 

Heat pump stopped

 

Call an authorized technician

 

 

 

 

 

Short circuit in water

 

Reset the heat pump from the

Sc

temperature sensor

The water temperature sensor is

breaker

 

incorrectly plugged or defective

 

 

 

 

 

Heat pump stopped

 

Call an authorized technician

 

 

 

 

 

 

 

Reset the heat pump from the

 

 

 

breaker

 

 

Loss of refrigerant

Call an authorized technician

 

Low pressure detected in

 

 

LP

circuits

Defective captor or cable

Call an authorized technician

 

 

 

 

Heat pump stopped

Defective fan

Call an authorized technician

 

 

Dirty evaporator

Clean the evaporator

 

 

Defrosting captor is defective

Call an authorized technician

 

 

 

Reset the heat pump from the

 

High pressure detected in

 

breaker

 

circuits

 

 

HP

 

Water flow either slow or blocked

Adjust the water flow

Working resumption when

by an obstruction

 

 

 

 

the pressure becomes

 

 

 

normal again

Defective captor or cable

Call an authorized technician

 

 

 

 

 

 

Water flow either slow or blocked

Adjust the water flow

 

4 high pressures detected

by an obstruction

Clean pool filter

HP4

in circuits

 

Reset the heat pump from the

 

 

breaker

 

 

 

 

Heat pump stopped

 

 

 

 

Defective captor

Call an authorized technician

 

 

 

 

22

Image 22
Contents Pool Heat Pump Table of Contents Cost-efficient Heater Low MaintenanceIntroduction How Does It Work?Selecting the Location Air Supply and AccessibilityOther Recommendations Water Inlet and Outlet Connections Chlorinators, Brominators and Other Automatic Systems Basic ConnectionPressure-type Chlorinator or Brominator Salt Chlorinator In-line Chlorinator or BrominatorDual Unit Connection Using One Pump and One Filter for the Pool and the Spa Pool and SPA ConnectionElectrical Connection Winterizing Cupro-nickel heat exchanger MaintenanceCleaning Winterizing Titanium heat exchangerWinterizing Titanium heat exchanger Seasonal Start-up Water DeviationWhy Perform Water Maintenance? Water MaintenanceWater Chemistry PH of Various Chemical Products for Pools Sanitizers Shock TreatmentBromine Testing What to do?Swimming Pool Heatpump Control Instrument Identification Operation To Enter the Service Mode Error Code List Code Symptom Probable Cause Solution Solving Problems Error Possible Causes Possible SolutionsQuestions and Answers Warranty Pool Heat PumpsLimited Warranty 690, Place Trans-Canada Longueuil, QC, J4G 1P1

Pool Heat Pump specifications

The Taylor Pool Heat Pump is a state-of-the-art heating solution designed to provide efficient and effective temperature control for swimming pools. Emphasizing energy efficiency and environmental sustainability, this advanced heat pump utilizes cutting-edge technology to ensure optimal performance while minimizing operational costs.

One of the key features of the Taylor Pool Heat Pump is its inverter technology. This innovation allows the unit to adjust its heating output based on the pool's current temperature, ensuring that it operates at the most efficient level. By running at variable speeds, the heat pump can maintain steady water temperatures without the significant energy spikes associated with traditional heating systems. This efficiency helps pool owners save money on energy bills while still enjoying a comfortably heated swimming environment.

Another notable characteristic of the Taylor Pool Heat Pump is its high COP (Coefficient of Performance). This metric indicates how effectively the heat pump converts electrical energy into heat. With a COP that frequently exceeds 5.0, the Taylor Pool Heat Pump showcases its ability to deliver more than five units of heating for every unit of electricity consumed, making it one of the most powerful and efficient options on the market.

The construction of the Taylor Pool Heat Pump is also designed to withstand the elements. Featuring a durable casing and weather-resistant components, the unit is built to endure harsh outdoor conditions without compromising performance. This robustness extends the lifespan of the heat pump, making it a reliable choice for pool owners who seek long-term heating solutions.

Additionally, the Taylor Pool Heat Pump operates quietly, thanks to its advanced sound-dampening features. This design consideration allows users to enjoy their pool area without the distraction of loud mechanical noises, making it a pleasant environment for relaxation and entertainment.

For ease of use, the Taylor Pool Heat Pump incorporates smart technology, enabling remote control and monitoring via smartphone applications. This modern feature allows pool owners to adjust settings, track energy usage, and schedule heating cycles, all from the convenience of their mobile devices.

In summary, the Taylor Pool Heat Pump stands out with its inverter technology, high COP, durable construction, quiet operation, and smart capabilities. Together, these features create a comprehensive and user-friendly heating solution that enhances the pool experience while promoting energy efficiency and sustainability. Whether used in residential or commercial settings, the Taylor Pool Heat Pump is designed to meet the diverse needs of pool owners worldwide.