Pentair MT warranty 20010900

Page 18

Page 18

 

 

Pentair Water Commercial Pool and Spa

 

 

 

 

 

 

 

 

 

Key

 

Size

Size

Size

Size

Size

Size

Size

No.

Description

2000 I

2450 I

3050 I

3500 I

4050 I

4500 I

5000 I

 

 

 

2200 E

2800 E

3200 E

3600 E

4000 E

4500 E

22.

Lock Washer - 3/8"

F0010800

F0010800

F0010800

F0010800

F0010800

F0010800

F0010800

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

23.

Washer - 3/8"

F0011100

F0011100

F0011100

F0011100

F0011100

F0011100

F0011100

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

24.

Cap Screw

F0015900

F0015900

F0015900

F0015900

F0015900

F0015900

F0015900

 

3/8" - 16UNC x ¾ "

(2)

(2)

(2)

(2)

(2)

(2)

(2)

25.

Heat Exchanger Baffle Assembly 20010900

20010900

20010900

20010900

20010900

20010900

20010900

 

 

(68)

(68)

(68)

(102)

(102)

(102)

(102)

26.

Heat Exchanger Baffle F & R

10534310

10534311

10534312

10534313

10534314

10534315

10534316

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

27.

Front & Rear Closure

20006401

20006402

20006403

20006404

20006405

20006406

20006407

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

28.

Inside Baffle Assembly Indoor

20012501

20012502

20012503

20012504

20012505

20012506

20012507

 

Outdoor

N/A

20012509

20012510

20012511

20012512

20012513

20012514

29.

Flue Panel Assembly, F&R

20011501

20011502

20011503

20011504

20011505

20011506

20011507

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

30.

Upper Panel

20011701

20011702

20011703

20011704

20011705

20011706

20011707

 

F & R (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

31.

Flue Diverter Assembly

20012201

20012202

20012203

20012204

20012205

20012206

20012207

 

(indoor only)

 

 

 

 

 

 

 

32.

Upper Wing

20006301

20006301

20006301

20006301

20006301

20006301

20006301

 

F & R, Left (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

33.

Upper Wing

20006302

20006302

20006302

20006302

20006302

20006302

20006302

 

F & R, Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

34.

Top Panel Assembly

20012301

20012302

20012303

20012304

20012305

20012306

20012307

 

(indoor only)

 

 

 

 

 

 

 

35.

Flue End Assembly

20012000

20012000

20012000

20012000

20012000

20012000

20012000

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

36.

Upper End Assembly

20011900

20011900

20011900

20011900

20011900

20011900

20011900

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

37.

Lower End Panel Assembly

20011800

20011800

20011800

20011800

20011800

20011800

20011800

 

 

(2)

(2)

(2)

(2)

(2)

(2)

(2)

38.

Control Mounting Panel

20013700

20013700

20013700

20013700

20013700

20013700

20013700

39.

Control Cover - Front

20018700

20018700

20018700

20018700

20018700

20018700

20018700

40.

Control Box Cover Top

20011200

20011200

20011200

20011200

20011200

20011200

20011200

41.

Pilot Lead Assembly (Johnson)

20035403

20035403

20035403

20035403

20035403

20035403

20035403

 

Standing Pilot, Nat/Propane

 

 

(2)

(2)

(2)

(2)

(2)

 

Pilot Lead Assembly (Honeywell) 20035404

20035404

20035404

20035404

20035404

20035404

20035404

 

Standing Pilot, Nat/Propane

 

 

(2)

(2)

(2)

(2)

(2)

 

Pilot Lead Assembly (Johnson)

20035401

20035401

20035401

20035401

20035401

20035401

20035401

 

IID Pilot, Nat

 

 

(2)

(2)

(2)

(2)

(2)

 

Pilot Lead Assembly (Honeywell) 20035402

20035402

20035402

20035402

20035402

20035402

20035402

 

IID Pilot, Nat

 

 

(2)

(2)

(2)

(2)

(2)

42.

Pilot Shield

20016400

20016400

20016400

20016400

20016400

20016400

20016400

 

 

 

 

(2)

(2)

(2)

(2)

(2)

43.

Draft Hood Relief

20013801

20013801

20013801

20013801

20013802

20013803

20013804

 

Baffle - Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

44.

Draft Hood Relief

20013805

20013805

20013805

20013805

20013806

20013807

20013808

 

Baffle - Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

45.

Manual Valve

V0001800

V0001800

V2013800

V2013800

V2013800

V2013900

V2013900

46.

Safety Valve (U.S.)

V0046800

V0046800

V0046900

V0046900

V0046900

V2000500

V2000500

 

Lubricated Plug Valve (Canada)

V0020500

V0020500

V0020600

V0020500

V0020500

V0020500

V0020500

 

 

 

 

 

(2)

(2)

(2)

(2)

47.

Operating Valve

V0047800

V0047800

V0047900

V0047700

V0047800

V0047800

V0047800

 

 

 

 

 

(2)

(2)

(2)

(2)

I=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted.

Image 18
Contents MegaThermTM Table of Contents General Information Installation2A. Boiler Placement 1A. Introduction2B. Installation of Indoor Boilers 2B-1. Combustion Air Supply2C. Installation of Outdoor Units 2B-2. Venting2D. Freeze Protection 2E. Gas Supply and Piping2F. Electrical Wiring 2G. Piping of System to Boiler2H. General Water Piping 2K. Pressure Switch 2I. Boiler By-Pass Piping2J. Automatic Chlorinators 3A-1. Initial Filter Cycle on a New Pool Operation3A. Initial Start-Up 3A-2. Starting Instructions3D. Spring and Fall Operation 3B. To Start Up System See a for Initial Start Up3C. To Turn Off Boiler 3E. Winter Operation3F. Time Clock Operation 3G. Spa Hot Tub Safety Rules3H. Periodic Service 3I. Pool Water ChemistryMaintenance Pilot LocationTroubleshooting and Analysis Service Problems Possible Cause What To DoParts List for Conversion 6B. Section II See FigureOutdoor Parts. Referenced on Parts Description and Order Numbers 16Pentair Water Commercial Pool and SpaParts Identification 20010900 Built-in Automatic Control Valve 472644 Rev a 05/22/06

MT specifications

Pentair MT is a versatile and innovative product designed for a wide range of water treatment applications, catering to both residential and commercial needs. Known for its superior performance and reliability, Pentair MT incorporates advanced technologies to provide efficient water management solutions.

One of the standout features of Pentair MT is its ability to deliver high flow rates while maintaining optimal water quality. This is achieved through a combination of cutting-edge filtration technologies and smart monitoring systems. The product is equipped with multi-stage filtration, allowing for the removal of impurities, sediments, and harmful microorganisms, ensuring that the water is clean and safe for consumption.

Energy efficiency is another hallmark of Pentair MT. The system is designed to minimize energy consumption without compromising performance, which not only reduces operational costs but also supports environmentally sustainable practices. The incorporation of energy-efficient pumps and motors enables users to enjoy substantial savings over time.

Pentair MT also features user-friendly controls that enhance the overall experience. The intuitive interface allows easy monitoring and adjustments, giving users full control over their water treatment processes. With real-time data and alerts, users can instantly be aware of the system’s status, making it easier to manage maintenance and ensure optimal performance.

In addition to its efficiency and ease of use, Pentair MT is designed for durability. Constructed with high-quality materials, the system is resistant to corrosion and wear, extending its lifespan and reducing the need for frequent replacements. This reliability makes it an ideal choice for various settings, including homes, offices, and industrial facilities.

Compatibility is another advantage of Pentair MT, as it can be integrated with existing plumbing systems and water sources with ease. Whether used for drinking water purification, irrigation, or other applications, Pentair MT adapts to the user's specific needs.

Overall, Pentair MT stands out as a leading solution in the water treatment market, offering advanced technologies, energy efficiency, user-friendly features, and durability. Its commitment to delivering high-quality water solutions makes it an essential tool for anyone looking to improve their water quality and management. This comprehensive approach to water treatment ensures that users can rely on Pentair MT for consistent performance and peace of mind.