Raypak CR24-495, RP-995, RP-045, CR24-185 Sample Installation Diagram, Controls

Page 6

Sample Installation Diagram

1.

Indirect Pool Heater

2.

 

TO BOILER CONTROL

BOILER WATER FLOW

 

Gate valve

3.

Check valve

4.

Flow switch

 

5.

Thermostat or Aquastat

6.

Thermometer

2

12

11

4

11

2

6

POOL WATER FLOW

3

7.

Drain valve

8.

Filter

9.

Pool/Spa Pump

10.

Bypass valve

11.

Union

12.

Boiler Pump

1

6

BOILER WATER FLOW

2

3 11

10

11

2

5

POOL WATER FLOW

7

8

9

NOTE:

-Damage to the Indirect Pool Heater due to improper water chemistry is not covered under the warranty

-Chlorine feeder must be installed after (downstream of) the Indirect Pool Heater and be installed with an anti-siphoning valve to prevent chlorine from backing up into the Indirect Pool Heater.

-This is only a conceptual drawing. A qualified installer must determine whether this system setup will work in each application. Installer must also ensure compliance with code requirements.

On the pool side the flow may be variable either due to variable speed pumps or changes in the pressure drop through the filtration system. These variances can be accommodated by installing a 2lb spring loaded check valve in the bypass line along with a manual valve (see Figure 2 for details).

On model sizes 045 to 495, the check valve will con- trol bypass flow by directing all flow through the exchanger under low flow conditions, and avoiding excessive flow through the heat exchanger under high flow conditions. On 995 models the 2lb check valve does not provide enough resistance to direct adequate flow through the heat exchanger, and must be aug- mented by using the manual valve to throttle flow to provide approximately 6 to 15 ft of head across the 995 exchanger.

Controls

The Indirect Pool Heater must be installed with tem- perature and flow control s to protect the heat exchanger and control water temperature supplied to the pool or spa. The return from the pool/spa must be controlled at the inlet to the Indirect Pool Heater by a thermostat set to the desired temperature for the pool/spa, with the maximum recommended operating

temperature of 104°F. A second temperature control must be installed in the outlet piping of the Indirect Pool Heater to limit pool/spa supply temperatures to 140°F maximum. In addition to the temperature con- trols, a flow switch should be installed in the pool/spa supply line to prove adequate flow through the heat exchanger. All three of these controls must be satis- fied to provide a call for heat to the heat source.

Chlorine feeders or salt water generators

The chlorine feeder or salt water generator (with CR24 exchangers only) must be installed after (downstream of) the Indirect Pool Heater and be installed with an anti-siphoning valve to prevent chlorine from backing up into the Indirect Pool Heater. During periods of high or fluctuating chlorine levels the Indirect Pool Heater must be isolated from the system by closing the isola- tion valves, protecting the unit from chemical damage.

CAUTION: Operating control, high limit and flow switch are NOT part of the Indirect Pool Heater. These items must be supplied separately.

6

Image 6
Contents Raypak Indirect Pool Heaters Water Chemistry Free Chlorine Must not Exceed 5 PPMPage RP-045 CR24 SS316L BTU/hr InchesSuper Alloy RP-075Plumbing FlowSample Installation Diagram ControlsLimited Warranty Raypak Indirect Pool Heaters HOW to Make a Warranty Claim

RP-995, CR24-185, RP-045, CR24-495 specifications

Raypak is a reputable name in the heating industry, known for its commitment to quality and innovation. Among its impressive lineup of products are the CR24-495, RP-045, CR24-185, and RP-995 models, each designed to cater to specific heating needs while ensuring efficiency and reliability.

The Raypak CR24-495 is a high-capacity, commercial-grade boiler renowned for its robust construction and exceptional performance. One of its main features is the use of a stainless steel heat exchanger, which enhances durability, provides excellent heat transfer, and minimizes the risk of corrosion. The CR24-495 also incorporates an advanced modulating gas burner, which adjusts the heat output based on demand, leading to fuel savings and consistent temperature control.

In contrast, the RP-045 model is tailored for residential applications, combining efficient heating with user-friendly features. This boiler is equipped with a digital LCD display that provides real-time system information and diagnostics, simplifying maintenance and operation. The RP-045 utilizes a compact design, making installation easy and convenient for smaller spaces. Its whisper-quiet operation ensures a peaceful environment, ideal for home settings.

The CR24-185 is another exceptional offering by Raypak, specifically designed for moderate commercial applications. This unit boasts a high thermal efficiency rating, ensuring maximum heat output while minimizing energy consumption. The CR24-185 also features a built-in temperature control system, which allows for precise temperature settings. Its versatility makes it suitable for various applications, including swimming pools and hydronic heating systems.

Finally, the RP-995 stands out as a powerhouse in the Raypak portfolio, capable of delivering high performance for larger heating demands. The RP-995 includes advanced control systems that allow for integration with building management systems, providing enhanced monitoring and control capabilities. This model employs a state-of-the-art combustion technology that ensures optimal fuel efficiency and reduced emissions, aligning with modern environmental standards.

In summary, Raypak's CR24-495, RP-045, CR24-185, and RP-995 models exemplify the brand's commitment to delivering innovative heating solutions. With advanced features such as high-efficiency heat exchangers, user-friendly controls, and robust construction, these models cater to a wide range of heating requirements, ensuring that customers enjoy reliable performance and long-term value. Whether for residential or commercial applications, Raypak continues to lead the way in heating technology.