Raypak 514-824 manual Importantnotice

Page 23

SECTION 5/TROUBLESHOOTING GUIDE

IMPORTANTNOTICE

These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.

MECHANICAL (FOR QUALIFIED SERVICE PERSONNEL ONLY)

PROBLEM

CAUSE

SOLUTION

Harmonics, or whining noise.

 

U.G.inoperative………………………………

Check movement by putting in hot water (110°F

 

 

 

or higher). If no movement, replace.

 

* Debris or restriction in system………………

Locate the restriction and remove. Flush system

 

 

 

and clean.

 

* Debris in gas line………………………………

Remove debris or blow out gas line.

 

 

Low flow………………………………………

Scale forming in heat exchanger-clean heat

 

 

 

exchanger and check pool pH and total alkalinity.

Heater going on and off continuously.

 

Dirty filter………………………………………

Backwash filter.

 

 

Low water level in pool………………………

Raise water level.

 

 

External bypass setting out of

 

 

 

adjustment…………………………………….

Adjust bypass

 

* Pressure switch out of

 

 

 

adjustment……………………………………..

Adjust pressure switch

Liming or scale forming on heat

 

Pool water………………………………………

See Water Chemistry page 2.

exchanger.

 

 

 

Sooting

 

High flow rates…………………………………

Reduce by adding manual bypass valve and

 

 

 

adjust by putting thermometer in header (1/4”

 

 

 

NPT) drain opening. Set bypass so thermometer

 

 

 

reads between 105° and 110°F.

 

 

U.G.Inoperative………………………………

Check movement by putting in hot water (110°

 

 

 

or higher). If no movement, replace.

 

*

Air starvation……………………………………

Refer to installation instructions.

 

*

Improperventing………………………………

Follow recommended installation instructions.

 

* Insects or debris clogging

 

 

 

burner intake ports……………………………

Clean burners.

Pilot outage.

 

Low gas pressure………………………………

Adjust gas pressure.

 

 

Restricted pilot………………………………..

Clean pilot.

 

 

Weak pilot generator…………………………

Replace pilot.

Yellow lazy flame

 

Low gas pressure………………………………

Adjust gas pressure.

 

* Insects or debris clogging

 

 

 

burner intake ports……………………………

Clean burners.

Outer jacket very hot

* Broken refractory caused by

(paint blistered)

shipping damage or improper combustion……

 

Excessive sooting of heat

 

exchanger……………………………………...

Takes long time to heat pool or spa.

Calculate temperature in °/hr…………………

Filter not running long enough………………

Dirty filter………………………………………

Gas line or meter undersized…………………

Replace refractory panels.

Determine cause of sooting & correct.

Heat rise (°/hr.) = Heater output ÷ (Pool gallonage x 8.33) or refer to heater sizing chart.

This does not take into account heat loss due to weather.

Reset time clock. Clean filter.

Refer to installation instructions.

(*Usually occurs on initial start-up)

23

Image 23
Contents What to do if YOU Smell GAS Installation Operating Instructions CommercialWaterchemistry Contents Water START-UP Procedures Before START-UPFor Your Safety Read Before Operating BurnersTo Turn OFF GAS to Appliance Operating InstructionsVisual Inspection Maintenance and Care ProceduresWater Pressure Switch After START-UPImportant Notice Basic Tips if Heater will not FirePool & SPA Water Chemistry California Proposition 65 WarningClearances Base InstallationVent Piping Indoor HeaterStep #2 Venting Connections223.1/NFPA GAS Pressure Regulator GAS Supply ConnectionsCompanionflangeconnections Pipe Sizing for GAS ConnectionsPlumbing for Water Connections Location Flow Rates Model Pipe Size MIN. GPM MAX. GPMUnithermgovernoroperation Auxiliary Bypass Valve AdjustmentPressure Relief Valve Installation AUTOMATICCHLORINATORSANDCHEMICALFEED- ERSS8600 Ignition Control Electrical WiringPage Page Page Page Servicing Insructions CONTROLS/ADJUSTMENTS/REPLACEMENTSTypical Comfortable SPA Temperature Range KnobstopadjustmentPilot Safety Pressure SwitchPressure Switch Adjustment Pressure Switch Adjustment RangeRaypak Tube Cleaning KIT Combustionchamberremoval DesootingprocedureUNITHERMGOVERNORU.G.REPLACEMENT Importantnotice Liming Highvoltage Troubleshooting Honeywell S8600Electrical Raypak, Inc Eastman Ave Oxnard, CA Replacement Parts ListThis page is empty Pilot ASSEMBLY- Electronic Ignition Page Page
Related manuals
Manual 32 pages 11.75 Kb

514-824 specifications

The Raypak 514-824 is a leading model in the realm of heating solutions, specifically designed for outdoor residential and commercial applications. Known for its efficiency and durability, the Raypak 514-824 has gained popularity among users looking for reliable heating systems.

One of the standout features of the Raypak 514-824 is its advanced design that incorporates high-quality materials ensuring longevity. This model is constructed with a robust heat exchanger, typically made of copper or bronze, which promotes better thermal conductivity while resisting corrosion. This ensures that the unit maintains a high performance level even after prolonged use, making it an excellent choice for areas with varying weather conditions.

The technological aspects of the Raypak 514-824 are also impressive. It is equipped with an intuitive digital control system that allows for precise temperature adjustments. Users can easily set their desired temperature, which is maintained automatically, providing comfort with minimal manual control. The digital display is user-friendly, making it simple to monitor system performance and adjust settings as needed.

Efficiency is a critical characteristic of the Raypak 514-824. With a focus on energy-saving capabilities, this heater exceeds industry standards, often achieving efficiency ratings that minimize energy consumption. This not only results in cost savings on utility bills but also contributes to environmental sustainability, making it a more responsible choice for heating needs.

Safety features are paramount in the design of the Raypak 514-824. It includes various protections such as high-limit switches and pressure regulators that help prevent overheating and maintain optimal operating conditions. These safety measures ensure that the unit operates reliably and minimizes risks associated with traditional heating systems.

Furthermore, installation versatility sets the Raypak 514-824 apart. It is designed for straightforward installation, suitable for various setups whether it's integrated with a swimming pool or spa heating system. This adaptability makes it an ideal selection for anyone looking to enhance their outdoor space with effective heating solutions.

In summary, the Raypak 514-824 is a high-performing, efficient, and versatile heating model that combines modern technology with significant safety features. Its emphasis on user-friendly operation and long-lasting materials makes it a top contender in the heating market, catering to both residential and commercial applications. The Raypak 514-824 exemplifies a commitment to quality, efficiency, and reliability.