Raypak 105B installation instructions Operating and Installation Instructions

Page 1

OPERATING AND INSTALLATION INSTRUCTIONS

Model

105B Cast Iron

VERSA

ABOVE GROUND POOL and

SPA HEATER

CATALOG NO. 6100.60A

Effective: 10-1-99

Replaces: 6-15-99

Fig. # 9258

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

¥Do not try to light any appliance.

¥Do not touch any electrical switch; do not use any phone in your building.

¥Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

¥If you cannot reach your gas supplier, call the fire department.

This manual should be maintained in legible condition and kept adjacent to the heater or kept in a safe place for future reference.

Part No. 240776

Image 1
Contents Operating and Installation Instructions Contents Before START-UP For Your Safety Read Before OperatingBurners WaterLighting Instructions Millivolt SystemTo Turn OFF GAS to Appliance Operating Instructions Electronic Ignition SystemsAfter START-UP Water Pressure SwitchVisual Inspection Main Burner FlamePool & SPA Water Chemistry Winterizing the SPA HeaterBasic Tips if Heater will not Fire Cold Weather OperationAmbient Temperature Rating of Heater COM- Ponents Base InstallationCode Requirements Important NoticeALL Heaters ClearancesOutdoor Heaters Outdoor Units only High Wind ConditionsIndoor Heaters IndoortopStep Venting ConnectionsOutdoortop ScrewsZ223.1 Vent PipingPipe Sizing for GAS Connections GAS Supply ConnectionsPlumbing for Water Connections Millivolt System Electrical WiringElectronic Intermittent Ignition Device System IID Wiring Diagram KEY Wiring Diagram Millivolt UnitsIgnition Device Honeywell Wiring Diagram I.I.D. UnitsIgnition Device Robertshaw Wiring Diagram IID UnitsPressure Switch CONTROLS/ADJUSTMENTS ReplacementsTemperature Controls General Location of ControlsHigh Limits Pilot SafetyHigh Limit Removal TWO Speed PumpsBurner Drawer Removal Pilot Removal and CleaningGAS Valve Removal Main Burner and Orifice RemovalTube Replacement Procedure Tube Cleaning ProcedureDesooting Procedure Combustion Chamber RemovalMechanical for Qualified Service Personnel only Trouble Shooting GuideElectrical Millivolt High Voltage Troubleshooting Honeywell S8600Raypak, Inc Agoura Road Westlake Village, CA Replacement Parts List12-P 13-P 14-P 15-P IIDPage Page Warranty Exclusion

105B specifications

Raypak 105B is a well-engineered boiler designed for various heating applications. Known for its efficiency and reliability, the Raypak 105B is a preferred choice among professionals in both residential and commercial settings.

One of the main features of the Raypak 105B is its compact design. Measuring in at a size that allows for easy installation, it is ideal for locations where space is at a premium. The unit's lightweight materials contribute to a reduced load on structural components of buildings, making it an efficient option for retrofits and new installations alike.

The Raypak 105B operates on advanced technology that ensures optimal performance and energy efficiency. The unit boasts a high thermal efficiency rating, which translates to lower operational costs for users. Its innovative control system monitors and adjusts the heating output, ensuring that the boiler operates at peak efficiency while maintaining comfort.

Another significant characteristic of the Raypak 105B is its built-in hydrostat. This feature automatically controls water temperature, providing a safeguard against overheating and improving overall safety. The unit's durable stainless steel heat exchanger enhances the longevity of the product while also resisting corrosion, a common issue in boiler systems.

In terms of environmental considerations, the Raypak 105B is designed to meet or exceed industry standards for emissions. This not only helps users comply with regulations but also contributes to a reduced carbon footprint. Additionally, the natural gas or propane options add versatility in terms of fuel choice, catering to a wide range of applications.

Ease of maintenance is another advantage offered by the Raypak 105B. The unit is designed to provide straightforward access to key components, minimizing operational downtime when servicing is needed. This thoughtful design element supports both residential and commercial needs, ensuring reliability in various settings.

In summary, the Raypak 105B stands out due to its compact design, high thermal efficiency, advanced control systems, and robust safety features. With its focus on longevity, ease of maintenance, and environmental compliance, the Raypak 105B continues to be a leading choice for efficient heating solutions in diverse applications. Its reputation for reliability makes it a trusted option for those in need of dependable heating solutions.