Raypak 105B installation instructions Electrical Wiring, Millivolt System

Page 15

ELECTRICAL WIRING

NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105 °C wire or its equivalent, except all black wire must be replaced with 150 °C wire or its equivalent.

MILLIVOLT SYSTEM

The Millivolt System Residential Heater is equipped with a self-generating electrical system in which the electric current is provided by means of a pilot generator. No external electrical connections are required.

ELECTRONIC INTERMITTENT IGNITION DEVICE SYSTEM (IID)

NOTE: When the electrical hookup to the heater requires both 24V and 115V or 240V, each input voltage must be isolated in separate conduit.

The Electronic Intermittent Ignition Device automati- cally lights the pilot and main burners upon a call for the heat. The heater is supplied with a dual voltage trans- former for 120V or 240V input power hookup.

NOTE: IID Propane Units Only

Heater is equipped with an electronic ignition device with a 100% safety lockout feature. If the heater fails to start or lockout. Reset the ignition device by interrupting the power to the heater for 60 seconds.

CAUTION: If service replacement of the electronic igni- tion device is required. Replace only with a 100% safety lockout device with 90 second trial for pilot ignition.

For 120 V input power to the unit, connect the black wire to the ÒL1Ó or hot leg of the power supply. Connect the white wire to the ÒL2Ó or neutral leg of the power supply. Attach the wire nut to the red wire. There should be no connection to the red wire for 120V operation.

Fig. #9240

For 240 V input power to the unit, connect the black wire to the ÒL1Ó or hot leg of the power supply. Connect the red wire to the ÒL2Ó or second hot leg of the power supply. Attach the wire nut to the white wire. There should be no connection to the white wire for 240V operation.

Fig. # 8085

 

Robertshaw Intermittent

 

Ignition Device

 

Honeywell Intermittent

Fig. # 8929.1

Ignition Device

Fig. # 9241

Heater must be electrically grounded and bonded in accordance with local codes, or, in the absence of local codes, with the latest edition of the National Electrical code, ANSI/NFPA 70.

NOTE: Input power to the heater (120/240V) should be supplied from the load (Pump) side of time clock or switch. Connecting heater to continuous power source will allow "Fail" indications (service and pressure switch) when pump is not operating.

14

Image 15
Contents Operating and Installation Instructions Contents Water For Your Safety Read Before OperatingBefore START-UP BurnersMillivolt System Lighting InstructionsTo Turn OFF GAS to Appliance Operating Instructions Electronic Ignition SystemsMain Burner Flame Water Pressure SwitchAfter START-UP Visual InspectionCold Weather Operation Winterizing the SPA HeaterPool & SPA Water Chemistry Basic Tips if Heater will not FireImportant Notice Base InstallationAmbient Temperature Rating of Heater COM- Ponents Code RequirementsClearances ALL HeatersOutdoor Heaters Indoortop High Wind ConditionsOutdoor Units only Indoor HeatersScrews Venting ConnectionsStep OutdoortopZ223.1 Vent PipingPipe Sizing for GAS Connections GAS Supply ConnectionsPlumbing for Water Connections Electrical Wiring Millivolt SystemElectronic Intermittent Ignition Device System IID Wiring Diagram KEY Wiring Diagram Millivolt UnitsIgnition Device Honeywell Wiring Diagram I.I.D. UnitsIgnition Device Robertshaw Wiring Diagram IID UnitsGeneral Location of Controls CONTROLS/ADJUSTMENTS ReplacementsPressure Switch Temperature ControlsTWO Speed Pumps Pilot SafetyHigh Limits High Limit RemovalMain Burner and Orifice Removal Pilot Removal and CleaningBurner Drawer Removal GAS Valve RemovalCombustion Chamber Removal Tube Cleaning ProcedureTube Replacement Procedure Desooting ProcedureMechanical for Qualified Service Personnel only Trouble Shooting GuideElectrical Millivolt High Voltage Troubleshooting Honeywell S8600Raypak, Inc Agoura Road Westlake Village, CA Replacement Parts List12-P 13-P 14-P 15-P IIDPage Page Warranty Exclusion

105B specifications

Raypak 105B is a well-engineered boiler designed for various heating applications. Known for its efficiency and reliability, the Raypak 105B is a preferred choice among professionals in both residential and commercial settings.

One of the main features of the Raypak 105B is its compact design. Measuring in at a size that allows for easy installation, it is ideal for locations where space is at a premium. The unit's lightweight materials contribute to a reduced load on structural components of buildings, making it an efficient option for retrofits and new installations alike.

The Raypak 105B operates on advanced technology that ensures optimal performance and energy efficiency. The unit boasts a high thermal efficiency rating, which translates to lower operational costs for users. Its innovative control system monitors and adjusts the heating output, ensuring that the boiler operates at peak efficiency while maintaining comfort.

Another significant characteristic of the Raypak 105B is its built-in hydrostat. This feature automatically controls water temperature, providing a safeguard against overheating and improving overall safety. The unit's durable stainless steel heat exchanger enhances the longevity of the product while also resisting corrosion, a common issue in boiler systems.

In terms of environmental considerations, the Raypak 105B is designed to meet or exceed industry standards for emissions. This not only helps users comply with regulations but also contributes to a reduced carbon footprint. Additionally, the natural gas or propane options add versatility in terms of fuel choice, catering to a wide range of applications.

Ease of maintenance is another advantage offered by the Raypak 105B. The unit is designed to provide straightforward access to key components, minimizing operational downtime when servicing is needed. This thoughtful design element supports both residential and commercial needs, ensuring reliability in various settings.

In summary, the Raypak 105B stands out due to its compact design, high thermal efficiency, advanced control systems, and robust safety features. With its focus on longevity, ease of maintenance, and environmental compliance, the Raypak 105B continues to be a leading choice for efficient heating solutions in diverse applications. Its reputation for reliability makes it a trusted option for those in need of dependable heating solutions.