| XLS Series Power Amplifiers | |
6 Specifications |
|
|
|
| ||
|
|
|
|
| ||
| Minimum Guaranteed Power | XLS 202 | XLS 402 | XLS 602 |
| |
|
|
|
|
|
| |
| 120 VAC, 60 Hz Units, per channel, both channels driven |
|
|
|
| |
|
|
|
|
|
| |
| 1 kHz with 0.5% THD |
|
|
|
| |
|
| Stereo, 2 ohms (per ch.) | 250W | 570W | 840W | |
|
| Stereo, 4 ohms (per ch.) | 200W | 400W | 600W | |
|
| Stereo, 8 ohms (per ch.) | 145W | 260W | 370W | |
|
| 400W | 800W | 1,200W | ||
|
| 500W | 1,140W | 1,680W | ||
|
|
|
|
|
| |
| 240 VAC, 50 Hz Units, per channel, both channels driven |
|
|
|
| |
|
|
|
|
|
| |
| 1 kHz with 0.5% THD |
|
|
|
| |
|
| Stereo, 2 ohms (per ch.) | 250W | 610W | 880W | |
|
| Stereo, 4 ohms (per ch.) | 225W | 445W | 670W | |
|
| 500W | 1,120W | 1,760W | ||
|
|
|
|
| ||
| Performance | XLS 202 | XLS 402 | XLS 602 |
| |
|
|
|
|
|
| |
| Sensitivity (volts RMS) for full rated power at 4 ohms | 0.725 | 1.025 | 1.26 |
| |
| Frequency Response (at 1 watt, 22 Hz - 20 kHz) | ± 0.75 dB | ± 0.75 dB | ± 0.75 dB | ||
|
|
|
|
|
| |
| Phase Response (at 1 watt, 10 Hz, 20 kHz) | |||||
|
|
|
|
|
| |
| Signal to Noise Ratio below rated power (20 Hz to 20 kHz) |
|
|
|
| |
|
| > 100 dB | > 100 dB | > 100 dB | ||
|
| No weighting, below rated power | > 95 dB | > 95 dB | > 95 dB | |
|
|
|
|
|
| |
| Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20 Hz to 1 kHz | < 0.5% | < 0.5% | < 0.5% |
| |
|
|
|
|
|
| |
| Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, | < 0.3% | < 0.3% | < 0.3% |
| |
| from full rated output to |
|
|
|
| |
|
|
|
|
|
|
|
page 16 | Operation Manual |