Crown Audio XLS Series operation manual Specifications, Minimum Guaranteed Power XLS

Page 16

 

 

 

 

 

XLS Series Power Amplifiers

6 Specifications

 

 

 

 

 

 

 

 

 

 

Minimum Guaranteed Power

XLS 202

XLS 402

XLS 602

 

 

 

 

 

 

 

 

120 VAC, 60 Hz Units, per channel, both channels driven

 

 

 

 

 

 

 

 

 

 

 

1 kHz with 0.5% THD

 

 

 

 

 

 

Stereo, 2 ohms (per ch.)

250W

570W

840W

 

 

Stereo, 4 ohms (per ch.)

200W

400W

600W

 

 

Stereo, 8 ohms (per ch.)

145W

260W

370W

 

 

Bridge-Mono, 8 ohms

400W

800W

1,200W

 

 

Bridge-Mono, 4 ohms

500W

1,140W

1,680W

 

 

 

 

 

 

 

240 VAC, 50 Hz Units, per channel, both channels driven

 

 

 

 

 

 

 

 

 

 

 

1 kHz with 0.5% THD

 

 

 

 

 

 

Stereo, 2 ohms (per ch.)

250W

610W

880W

 

 

Stereo, 4 ohms (per ch.)

225W

445W

670W

 

 

Bridge-Mono, 4 ohms

500W

1,120W

1,760W

 

 

 

 

 

 

Performance

XLS 202

XLS 402

XLS 602

 

 

 

 

 

 

 

 

Sensitivity (volts RMS) for full rated power at 4 ohms

0.725

1.025

1.26

 

 

Frequency Response (at 1 watt, 22 Hz - 20 kHz)

± 0.75 dB

± 0.75 dB

± 0.75 dB

 

 

 

 

 

 

 

Phase Response (at 1 watt, 10 Hz, 20 kHz)

–10°, +19°

–10°, +19°

–10°, +19°

 

 

 

 

 

 

 

Signal to Noise Ratio below rated power (20 Hz to 20 kHz)

 

 

 

 

 

 

A-weighted, below rated power

> 100 dB

> 100 dB

> 100 dB

 

 

No weighting, below rated power

> 95 dB

> 95 dB

> 95 dB

 

 

 

 

 

 

 

Total Harmonic Distortion (THD) at 1 full bandwidth power, from 20 Hz to 1 kHz

< 0.5%

< 0.5%

< 0.5%

 

 

 

 

 

 

 

 

Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1,

< 0.3%

< 0.3%

< 0.3%

 

 

from full rated output to –40 dB

 

 

 

 

 

 

 

 

 

 

 

page 16

Operation Manual

Image 16
Contents XLS Some models may be exported under the name AmcronFCC Compliance Notice Safety Standard Declaration of ConformityCrown International, Inc European Representative’s Name and AddressTable of Contents How to Use This Manual FeaturesWelcome Setup Install Your AmplifierUnpack Your Amplifier Ensure Proper CoolingChoose Output Wire and Connectors Choose Input Wire and ConnectorsDistance Wire Your System Stereo Mode Bridge-Mono Mode 11 Bridge-Mono Wiring of 5-Way Binding PostsConnect to AC Mains Startup ProcedureProtecting Your Speakers Precautions OperationFront Panel Controls Indicators Cooling Vents Clip IndicatorsPower Indicator Fault IndicatorPower Connector Circuit Breaker Pole Speakon Output ConnectorsBalanced XLR Inputs FansAdvanced Features and Options Protection SystemsOutput Current Limiting DC ProtectionTroubleshooting Condition No power to the amplifierSpecifications Minimum Guaranteed Power XLSConstruction XLS AC Power Draw and Thermal Dissipation Following equation is used to calculate thermal dissipationXLS Btu/hr Service Warranty United States & CanadaWorldwide Except USA & Canada This page Intentionally Left Blank Crown Factory Service Information Nature of ProblemThis page Intentionally Left Blank XLS Series Power Amplifiers