Toro 860S specifications Introduction, Features, Specifications and Performance/Application Data

Page 1

860S and 880S Series Rotary Sprinklers

Installation & Service Instructions

Introduction _____________________________________________________________________

The 860S and 880S series full circle and adjustable part-circle rotary sprinklers are designed specifically for golf course applications.

Manufactured from durable, high-strength engineering plastic and stainless-steel components, the 800S series sprinklers incorporate many innovative and time- proven features for lasting, maintenance-free operation.

Prior to installing the sprinkler, read through the recommended installation and start-up procedures. Please observe all WARNINGS and CAUTIONS when installing and operating this equipment.

860S Electric VIH880S Electric VIH

Features ________________________________________________________________________

Adjustable part-circle (30°330°) and full circle models available

Arc adjustment from top of sprinkler

Standard stainless-steel riser resists scoring from embedded debris

Full 3" (7.6 cm) pop-up clears tall grasses

Nozzles color-coded by radius and gallonage

Cap serves as an effluent water indicator

Variable stator

Standard pressure regulation settings of 50 psi (3.4 bar), 65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar) to ensure consistently accurate nozzle performance regardless of elevation

Three body activation types available: Electric VIH, Normally Open Hydraulic VIH, and Check-O-Matic

Three body thread types available: NPT, BSP and ACME

Manual control at the sprinkler, On-Off-Auto (Electric only)

Bowl-vented discharge (atmospheric) minimizes the differential pressure required for regulation and ensures positive valve closure (electric models only)

All internal components serviceable from the top of the sprinkler

Large selection of color-coded nozzles available

Durable plastic and stainless-steel construction

Spike-GuardTMsolenoid for superior surge protection

Specifications and Performance/Application Data ______________________________________

860S Series

Radius: 54'–80' (16.4 m–24.4 m)

Flow Rate: 14.1–44.5 GPM (44.3–155.9 l/mn)

Trajectory: 25°

Arc: Full Circle or Adjustable Part Circle (30°–330°)

Recommended Operating Pressure: 50–100 PSI (3.4–6.9 bar)

Minimum Pressure: 40 PSI (2.8 bar)

Maximum Pressure: 150 PSI (10.3 bar)

Precipitation Rate:

Minimum: 0.37"/hr (9.4 mm/hr)

Maximum: 0.75"/hr (19.1 mm/hr)

Body Height: 10" (25.4 cm)

Pop-Up Height: 3" (7.6 cm)

1" NPT, BSP or ACME Female Thread Inlet

Spike GuardTM Solenoid:

24 V a.c., 50/60 Hz

Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)

60 Hz, 0.12 Amps (2.9 VA)

Holding Current: 50 Hz, 0.15 Amps (3.6 VA) 60 Hz, 0.10 Amps (2.4 VA)

Manual Control: On-Off-Auto

Check-O-Matic model checks up to 37' (11.2 m) of elevation.

Color-coded Nozzles (see nozzle color code chart, p. 3)

880S Series

Radius: 53'–83' (16.2 m – 25.3 m)

Flow Rate: 14.3–52.9 GPM (54.1–200.2 l/mn)

Trajectory: 25°

Arc: Full Circle or Adjustable Part Circle 30°–330°

Recommended Operating Pressure: 50–100 PSI (3.4–6.9 bar)

Minimum Pressure: 40 PSI (2.8 bar)

Maximum Pressure: 150 PSI (10.3 bar)

Precipitation Rate:

Minimum: 0.39"/hr (9.9 mm/hr)

Maximum: 0.74"/hr (18.8 mm/hr)

Body Height: 11" (27.9 cm)

Pop-Up Height: 3" (7.6 cm)

1.5" NPT, BSP or ACME Female Thread Inlet

Spike GuardTM Solenoid:

24 V a.c., 50/60 Hz

Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)

60 Hz, 0.12 Amps (2.9 VA)

Holding Current: 50 Hz, 0.15 Amps (3.6 VA) 60 Hz, 0.10 Amps (2.4 VA)

Manual Control: On-Off-Auto

Check-O-Matic model checks up to 37' (11.2 m) of elevation.

Color-Coded Nozzles (see nozzle color code chart, p. 3)

1

Image 1
Contents Specifications and Performance/Application Data FeaturesIntroduction Series Sprinkler Performance Data 860S Series Sprinkler Performance DataSprinkler Application Data Nozzle Color Code Sprinkler Spacing GuidelinesWire Sizing Chart Connecting Control Wires Electric Models OnlyConstructing Swing Joints System Start Up Connecting Hydraulic Control Tubing Hydraulic Models OnlyRecommended System Fill Rate Pipe Size Flow Velocity Troubleshooting Arc Adjustment Procedure Part-circle ModelsPilot Valve Operation Electric Models Only Pilot ValveMain Valve Sprinkler MechanismSprinkler Weeping Valve Wont OpenSlow leak in valve Servicing Sprinkler Mechanism Service ProceduresServicing Main Valve AC Power is Disconnected AT SourceServicing Pilot Valve Flushing Sprinkler