Toro 860S, 880S specifications Valve Wont Open, Sprinkler Weeping, Slow leak in valve

Page 7

VALVE WON'T OPEN

(a)

Control (field) wires severed.

(Electric)

 

– Isolate and repair.

 

(b)

No power to controller.

 

 

– Establish controller power.

 

(c)

No power from controller to solenoid.

 

 

– Check for blown fuse and replace.

 

(d)

Manual control selector on pilot valve assembly turned to "OFF" position.

 

 

– Turn to "AUTO" position.

 

(e)

Pilot valve solenoid inoperative.

 

 

– Remove and replace.

 

(f)

Pilot valve plunger movement restricted.

 

 

– Inspect, clean and/or replace.

 

(g)

No supply from main valve.

 

 

– Debris in control tube, main valve assembly and/or communication passages in

 

 

body. Flush thoroughly.

VALVE WON'T OPEN

(a)

Plugged controller discharge line or discharge port in pilot valve.

(Hydraulic)

 

– Verify by checking for discharge at discharge line when station is

 

 

activated. If no discharge, refer to Controller Service Manual.

SPRINKLER WEEPING

(a)

Damaged or blocked valve seat.

(Slow leak in valve)

 

– Remove blockage and, if necessary, replace valve assembly.

 

(b)

Damaged piston seal or piston assembly.

 

 

– Replace valve assembly.

 

(c)

Low pressure on supply line .

 

 

– Check for low pressure reason and correct.

 

(d)

Elevation of normally closed sprinkler exceeds 75' (22.9 m) differential.

SEVERAL VALVES ON DIFFERENT STATIONS FAIL TO CLOSE (Hydraulic)

(a)Control tubing leak which lowers supply pressure to other stations.

Turn controller from station to station until a station is reached where only valves on that station stay open. The leak would be in the tubing on that station. Isolate and repair.

(b)Leak in supply line to controller.

Verify by checking pressure in all control lines.

(c)Leak in controller pilot valve.

Verify by constant discharge from controller.

(d)Plugged supply line filter.

Replace filter if more than 3 psi (0.21 bar) differential exists.

7

Image 7
Contents Specifications and Performance/Application Data FeaturesIntroduction Nozzle Color Code Sprinkler Spacing Guidelines 860S Series Sprinkler Performance DataSeries Sprinkler Performance Data Sprinkler Application DataWire Sizing Chart Connecting Control Wires Electric Models OnlyConstructing Swing Joints System Start Up Connecting Hydraulic Control Tubing Hydraulic Models Only Recommended System Fill Rate Pipe Size Flow Velocity Pilot Valve Arc Adjustment Procedure Part-circle ModelsTroubleshooting Pilot Valve Operation Electric Models OnlyMain Valve Sprinkler MechanismSprinkler Weeping Valve Wont OpenSlow leak in valve Servicing Sprinkler Mechanism Service ProceduresServicing Main Valve AC Power is Disconnected AT SourceServicing Pilot Valve Flushing Sprinkler