Toro 730 specifications Connecting Hydraulic Control Tubing, System Start-Up, Control Systems

Page 3

Connecting Hydraulic Control Tubing

1.Route control tubing from controller to sprinkler location(s).

NOTE:

Leave an 18" (45.7 cm) service loop of tubing at each sprinkler to facilitate movement of sprinkler and service operations.

Tubing runs in excess of 1,000' (304.8 m) are not advisable due to delayed response time.

The valve elevation for normally open valve-in-head systems should not exceed 25' (7.6 m) above controller elevation or 70' (21.3 m) below controller elevation.

The valve elevation for normally closed valve-in-head systems should not exceed 0' above controller elevation or 70' (21.3 m) below controller elevation.

If connecting more than one VIH sprinkler per control tubing run, refer to the chart below.

 

Recommended

Maximum

1" VIH

3

5

1.5" VIH

2

3

2.Flush tubing thoroughly to remove all air and debris.

3.Remove tube retainer and poly cap from tubing adapter at base of sprinkler.

Table 2: Control Systems

 

Maximum Distance

 

Type of System*

From Controller

Elevation Restrictions

 

 

 

Pin-type£(00) Hydraulic*

 

 

with 316" Control Tubing

100'

 

 

 

 

Pin-type£(00) Hydraulic*

 

 

with 14" Control Tubing

200'

 

 

 

 

Normally Open (01)

 

Valve elevation should not exceed

with 316" Control Tubing

500'

25' ABOVE controller elevation or

 

 

70' BELOW controller elevation.

 

 

 

Normally Closed (08)

 

Valve elevation should not exceed

with 316" Control Tubing

500'

0' ABOVE controller elevation or

 

 

70' BELOW controller elevation.

 

 

 

Normally Open (01)

 

Valve elevation should not exceed

with 14" Control Tubing

1000'

25' ABOVE controller elevation or

 

 

70' BELOW controller elevation.

 

 

 

Normally Closed (08)

 

Valve elevation should not exceed

with 14" Control Tubing

1000'

0' ABOVE controller elevation or

 

 

70' BELOW controller elevation.

*- All hydraulic connections on Toro valves are 14" insert type.

-Control line pressure must be equal to or 10% greater than mainline pressure.

-Control line pressure range is 40 to 150 PSI

£NOTE: Maximum of one (1) valve pr station on pin-type systems.

4.Slide tube retainer over control tubing and attach tubing to adapter.

5.Slide tube retainer over adapter area to secure tubing.

System Start-Up

The following is a recommended procedure that will protect system components during system start-up. The procedure is based on a velocity fill rate of less than 2' (0.6 m) per second. SeeTable 2 below.

WARNING

DUE TO HIGH OPERATING PRESSURE, NEVER STAND OR LEAN DIRECTLY OVER TOP OF SPRINKLER OR COME IN CONTACT WITH SPRAY. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY.

1.Use jockey pump only to fill system at velocity fill rate of less than 2' (0.6 m) per second.

2.Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from system lines during filling process. Do not compress air and then relieve, bleed air while filling system.

3.After water has filled all lines and all air is removed, remove quick coupler keys.

CAUTION

Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer effect that could damage sprinklers and/or piping system.

Table 2: Recommended System Fill Rate

Pipe Size

Flow

Velocity

Pipe Size

Flow

Velocity

 

 

 

 

 

 

 

 

 

 

 

 

in.

cm

GPM

LPM

ft/sec

m/sec

in.

cm

GPM

LPM

ft/sec

m/sec

1/2

1.3

2

7.6

1.60

0.49

3

7.6

45

170.3

1.86

0.57

3/4

1.9

3

11.4

1.92

0.59

4

10.2

75

283.9

1.87

0.57

1

2.5

5

18.9

1.50

0.46

6

15.2

150

567.8

1.73

0.53

1-1/4

3.2

10

37.9

1.86

0.57

8

20.2

250

946.3

1.70

0.52

1-1/2

3.8

10

37.9

1.41

0.43

10

25.4

450

1703.3

1.97

0.60

2

5.0

20

75.7

1.80

0.55

12

30.5

500

1892.5

1.55

0.47

2-1/2

6.4

30

113.6

1.84

0.56

 

 

 

 

 

 

3

Image 3
Contents Conversion Installation & Service InstructionsFeatures SpecificationsConnecting Electric Control Wires Wire Sizing ChartSwing Joints Connecting Hydraulic Control Tubing System Start-UpControl Systems Head sticks up System Troubleshooting Pilot ValveSystem Troubleshooting Sprinklers Pilot Valve Operation Model 734-X6-XXX OnlySlow leak in valve Valve wont openElectric Sprinkler WeepingFlat Spot Down Servicing ProceduresIntroduction Servicing Sprinkler MechanismValve Removal and Replacement Flushing Sprinkler Heads Servicing Pilot Valve