Servicing Procedures
Introduction
The 734 sprinkler is designed to provide the user
WARNING
TO PREVENT POSSIBLE INJURY DURING SPRINKLER SERVICING PROCEDURES, CON-
FIRM THE FOLLOWING CONDITIONS EXIST PRIOR TO STARTING.
A. WATER SUPPLY TO SPRINKLER IS SHUT OFF AT SOURCE.
B. SYSTEM PRESSURE IS BLED FROM SYSTEM, INCLUDING CONTROL TUBES.
C. A.C. POWER IS DISCONNECTED AT SOURCE.
Servicing Sprinkler Mechanism
Refer to Toro Illustrated Parts Breakout Book, Form No.
1.Lift Cap using knife blade edge or small screwdriver tip inserted between edge of Cap and Body flange.
2.Grasping edges of Cap, pull sprinkler mechanism up until fully extended.
3.While firmly holding Riser Assembly, remove Cap/Nozzle assembly by turning it counterclockwise. Allow Riser Assembly to slowly retract into body.
4.Using two small screwdrivers inserted between Nozzle and Cap, separate Cap from Nozzle Assembly (retained by press fit).
5.To change Nozzles, carefully insert knife blade edge between nozzle flange and base. Pry nozzle loose and remove. Align new nozzle as shown in illustration at right. Carefully press new nozzles into Nozzle Base until flange is fully seated. Avoid contact with nozzle orifice as sprinkler coverage can be greatly impaired if orifice is damaged or altered in any way.
6.Using
7.Thread Drive Assembly Extraction Tool
8.Carefully remove
Flat
Spot
Down
Figure 2
9.Using
10.Remove Variable Stator.
11.Remove Drive Assembly by pushing against end of threaded output shaft.
12.Inspect Stator Housing for nicks and burrs. This part can be difficult to remove if sprinkler has been in operation for some time and should be left in place if it appears undamaged. If replacement is necessary, grasp housing with pliers and pull from riser housing.
13.Thoroughly clean and inspect all parts. Replace damaged parts as necessary and reassemble in reverse order.
6