DeVillbiss Air Power Company MGP-4600 owner manual Risk of Fire

Page 6

READ AND UNDERSTAND ALL WARNINGS BEFORE

ATTEMPTING TO OPERATE GENERATOR.

RISK OF FIRE

HAZARD

WHAT COULD HAPPEN

HOW TO PREVENT IT

 

 

 

Attempting to fill the fuel tank while the

Gasoline and gasoline vapors can

Turn engine off and allow it to cool

engine is running.

become ignited by coming in contact

before adding fuel to the tank. Equip

 

with hot components such as the

area of operation with a fire extin-

 

muffler, engine exhaust gases, or

guisher certified to handle gasoline

 

from an electrical spark.

or fuel fires.

Sparks, fire, hot objects

Cigarettes, sparks, fires, or other hot

Add fuel to tank in well ventilated

 

objects can cause gasoline or gaso-

area. Make sure there are no

 

line vapors to ignite.

sources of ignition near the genera-

 

 

tor.

 

 

 

Improper storage of fuel

Improperly stored fuel could lead to

Store fuel in a container designed

 

accidental ignition. Fuel improperly se-

to hold gasoline. Store container in

 

cured could get into the hands of chil-

secure location to prevent use by

 

dren or other unqualified persons.

others.

 

 

 

Inadequate ventilation for generator

Materials placed against or near the

Operate generator in a clean, dry,

 

generator can interfere with its proper

well ventilated area. Keep objects

 

ventilation features causing overheat-

away from unit during operation. DO

 

ing and possible ignition of the

NOT OPERATE UNIT IN A CON-

 

materials.

FINED AREA.

Tampering with factory set engine speed

Engine speed has been factory set to

Never attempt to “speed-up”the

settings.

provide safe operation. Tampering with

engine to obtain more performance.

 

the engine speed adjustment could re-

Both the output voltage and fre-

 

sult in overheating of attachments and

quency will be thrown out of stan-

 

could cause a fire.

dard by this practice, endangering

 

 

attachments and the user.

 

 

 

Overfilling the fuel tank – fuel spillage.

Spilled fuel and its vapors can become

Use care in filling the tank to avoid

 

ignited from hot surfaces or sparks.

spilling fuel. Check engine for fuel

 

 

leaks before starting. Move genera-

 

 

tor away from refueling area or any

 

 

spillage before starting engine. Al-

 

 

low for fuel expansion. Keep maxi-

 

 

mum fuel level 1/4 inch below the

 

 

top of the fuel tank.

 

 

 

6

Image 6
Contents Specification Chart DeVILBISSGENERATORTable of Contents Limited Warranty ONE Year from Date of Purchase Responsibility of Original Purchaser Initial UserSafety Guidelines Definitions Risk of Electrocution and Fire cont’d Risk of Fire Risk of Breathing Inhalation Hazard Risk of HOT Surfaces Wattage Calculating Instructions Wattage Calculating Instructions contd General Parts Identification Installation of Generator Grounding INSTRUCTIONS/EXTENSION CordsMaintenance Schedule Operating InstructionsMaintenance Parts List Troubleshooting GuideInstallation of Battery Recommended Battery for Electric StartGenerator Model no

MGP-4600 specifications

DeVillbiss Air Power Company is renowned for its innovative and reliable air-powered tools, and one of its standout products is the MGP-4600. This versatile air compressor is engineered to meet the demands of professionals and DIY enthusiasts alike, offering a wide range of features that enhance performance and usability.

The MGP-4600 boasts a powerful motor that delivers robust air pressure, making it suitable for a variety of applications, including spray painting, pneumatic tool operation, and inflation tasks. With a maximum pressure of 125 PSI, it provides ample power for even the most demanding jobs. The compressor is designed to be user-friendly, featuring an easy-to-read pressure gauge that allows users to monitor performance at a glance.

One of the key technologies employed in the MGP-4600 is its oil-free pump system. This design not only reduces maintenance needs but also eliminates the risk of oil contamination, ensuring clean air output for painting and other sensitive operations. The pump is durable and efficient, offering a longer lifespan and consistent performance under heavy use.

Portability is another hallmark of the MGP-4600. Weighing in at a manageable size, it features a compact design, making it easy to transport and store. The ergonomic handle and rubberized wheels further enhance mobility, allowing users to navigate various work environments with ease.

Additionally, the MGP-4600 incorporates advanced safety features, including a thermal overload protection system that prevents overheating, safeguarding both the unit and the user. This ensures that the compressor operates within safe temperature limits, promoting durability and reliability over time.

Noise reduction is also a significant characteristic of the MGP-4600. Its design minimizes operational noise, making it suitable for use in residential areas or indoor environments where sound levels must be kept in check.

The MGP-4600 air compressor is compatible with a range of accessories, facilitating its use with various tools and attachments. This adaptability makes it a valuable addition to any workshop or job site, ensuring it meets the diverse needs of its users.

In summary, the DeVillbiss Air Power Company MGP-4600 stands out with its powerful performance, user-friendly features, and innovative technologies. It is a reliable choice for anyone seeking an efficient, portable, and versatile air compressor, making it an essential tool for both professionals and home users alike.