Desa RN30E-CAN, RP30E-CAN installation manual What to do if YOU Smell GAS

Page 1

BLUE FLAME

VENT-FREE PROPANE AND NATURAL GAS GREENHOUSE CO2 GENERATOR

OWNER’S OPERATION AND INSTALLATION MANUAL

®

RN30E-CAN - Natural Gas

RP30E-CAN - Propane/LP Gas

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas- fired appliance. It uses air (oxygen) from the space in which it is installed. Provi- sions for adequate combustion and ven- tilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 3 of this manual.

WARNING: This appliance must not be washed. Use of a pressure washer, water or liquid cleaning solution on this appliance can cause severe personal injury or property damage due to water and/or cleaning solution:

In electrical components, connections and wires causing electrical shock or component failure.

On gas control components causing corrosion which can result in gas leaks and fire or explosion from the leak.

Appliance must be cleaned without being subjected to liquid spray or excessive wetting.

This appliance is only for use with the type of gas indicated on the rating plate.

This appliance is not convertible for use with other gases.

This appliance is not for residential use.

Save this manual for future reference.

DESA International • 2701 Industrial Drive • P.O. Box 90004 • Bowling Green, KY • 42102-9004

Image 1
Contents Save this manual for future reference What to do if YOU Smell GASIf you need assistance or ap- pliance information such as Safety InformationProduct Identification Product FeaturesAIR for Combustion and Ventilation Local CodesDetermining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationInstalling Appliance to Wall Check GAS TypeAttaching to Wall Stud Method Marking Screw LocationsTypical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Appliance Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Manual Lighting Procedure For Your Safety Read Before LightingOperating CO2 Generator Lighting InstructionsInspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Replacement Parts SpecificationsTechnical Service AccessoriesRP30E-CAN RN30E-CAN Illustrated Parts BreakdownODS/PILOT KEY Part Number Description QTY Parts ListLimited Warranty Blue Flame VENT-FREE CO2 Generator Warranty Information

RP30E-CAN, RN30E-CAN specifications

Desa RN30E-CAN and RP30E-CAN are cutting-edge compact portable generators that stand out in the market for their versatility and efficiency. Designed for a variety of applications, from camping trips to emergency power supply, these generators provide reliable performance in a compact format.

One of the key features of the RN30E-CAN and RP30E-CAN is their robust engine design. Powered by advanced gasoline engines, both models offer impressive starting capabilities and sustained power output. The RN30E-CAN produces a maximum output of 3,000 watts, while the RP30E-CAN takes it a step further with a peak output of 3,500 watts. This makes them ideal choices for powering essential devices, ranging from small appliances to larger equipment.

Efficiency is another hallmark of these generators. With a focus on fuel economy, both models incorporate innovative technologies that minimize fuel consumption while maximizing power. This not only helps save money but also reduces the environmental footprint of the generators. Users can take advantage of extended run times, making them perfect for longer outings or during unexpected outages.

In terms of user-friendly design, both RN30E-CAN and RP30E-CAN generators come equipped with intuitive control panels that simplify operation. The clear layout allows users to monitor power output and fuel levels effortlessly. Additionally, their lightweight construction, paired with integrated wheels and handles, enhances portability, making them easy to transport to any location.

Safety features are paramount in the design of the RN30E-CAN and RP30E-CAN. Equipped with automatic shutdown functions in the event of low oil levels and overload protection circuits, they provide peace of mind to users. The generators also boast a weather-resistant casing, ensuring durability and reliability even in adverse conditions.

Finally, both models are designed with noise reduction technology, making them quieter than many traditional generators. This makes them suitable for use in residential areas and during nighttime hours, allowing users to enjoy the benefits of portable power without disturbing their surroundings.

In summary, the Desa RN30E-CAN and RP30E-CAN generators combine power, efficiency, and safety into compact units that meet the needs of diverse users. Their advanced technology, ease of use, and portability make them excellent choices for anyone seeking reliable power on the go.