Desa RP30E-CAN Safety Information, If you need assistance or ap- pliance information such as

Page 2

BLUE-FLAME VENT-FREE PROPANE/LP AND

NATURAL GAS GREENHOUSE CO2 GENERATOR

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this appliance. Improper use of this appliance can cause serious injury or death from burns, fire,explosion,electricalshock,and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the appli- ance may not be working properly. Get fresh air at once! Have appliance serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP and Natural Gas: Propane/ LP and Natural gas are odorless. An odor- making agent is added to both gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this appliance.

GENERAL HAZARD WARN- ING: Failure to comply with the precautions and instructions provided with this appliance, can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.

If you need assistance or ap- pliance information such as

an instructions manual, labels, etc. Contact the manufacturer.

WARNING: Fire, burn, in- halation, and explosion haz- ard. Keep solid combustibles, such as building materials, paper or cardboard, feathers, straw and dust a safe distance away from the appliance as recommended by the instruc- tions. Never use the appliance in spaces which contain or may contain volatile or air- borne combustibles, or prod- ucts such as gasoline, sol- vents, paint thinner, dust par- ticles or unknown chemicals.

WARNING: Not for home or recreational vehicle use

WARNING: Any change to this appliance or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.Never install the CO2 generator

in a home

in a recreational vehicle

where flammable objects are less than 36 inches from the front, top, or sides of the appliance

in high traffic areas

in windy or drafty areas

5.This appliance needs fresh, outside air ventilation to run properly. This appli- ance has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the appliance if not enough fresh air is available. See Air for Combustion and Ventilation, pages 3 through 5.

6.Keep all air openings in the front and bottom of appliance clear and free of debris. This will insure enough air for proper combustion.

7.If appliance shuts off, do not relight until you provide fresh, outside air. If appliance keeps shutting off, have it serviced.

8.Do not run CO2 generator

where flammable liquids or vapors are used or stored

under dusty conditions

9.Never place any objects on the appli- ance.

10.Surface of appliance becomes very hot when running appliance. Keep children and adults away from hot surface to avoid burns and clothing ignition. CO2 generator will remain hot for a time after shutdown. Allow surface to cool before touching.

11.Make sure grill guard is in place be- fore running appliance.

12.Carefully supervise young children when they are in same area with appliance.

13.Do not use appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

14.Turn off appliance and let cool before servicing. Only a qualified service per- son should service and repair CO2 generator.

15.Operating appliance above elevations of 4,500 feet could cause pilot outage.

16.To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity.

17.The CO2 generator should be inspected at least annually by a qualified service agency.

18.Do not operate appliance with front panel removed.

2

105056

Image 2
Contents What to do if YOU Smell GAS Save this manual for future referenceSafety Information If you need assistance or ap- pliance information such asAIR for Combustion and Ventilation Product FeaturesProduct Identification Local CodesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Appliance to Wall InstallationInstallation Items Check GAS TypeMarking Screw Locations Attaching to Wall Stud MethodConnecting to GAS Supply Typical Inlet Pipe DiametersChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Appliance Gas Connections Operating CO2 Generator For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Technical Service SpecificationsReplacement Parts AccessoriesODS/PILOT Illustrated Parts BreakdownRP30E-CAN RN30E-CAN Parts List KEY Part Number Description QTYWarranty Information Limited Warranty Blue Flame VENT-FREE CO2 Generator

RP30E-CAN, RN30E-CAN specifications

Desa RN30E-CAN and RP30E-CAN are cutting-edge compact portable generators that stand out in the market for their versatility and efficiency. Designed for a variety of applications, from camping trips to emergency power supply, these generators provide reliable performance in a compact format.

One of the key features of the RN30E-CAN and RP30E-CAN is their robust engine design. Powered by advanced gasoline engines, both models offer impressive starting capabilities and sustained power output. The RN30E-CAN produces a maximum output of 3,000 watts, while the RP30E-CAN takes it a step further with a peak output of 3,500 watts. This makes them ideal choices for powering essential devices, ranging from small appliances to larger equipment.

Efficiency is another hallmark of these generators. With a focus on fuel economy, both models incorporate innovative technologies that minimize fuel consumption while maximizing power. This not only helps save money but also reduces the environmental footprint of the generators. Users can take advantage of extended run times, making them perfect for longer outings or during unexpected outages.

In terms of user-friendly design, both RN30E-CAN and RP30E-CAN generators come equipped with intuitive control panels that simplify operation. The clear layout allows users to monitor power output and fuel levels effortlessly. Additionally, their lightweight construction, paired with integrated wheels and handles, enhances portability, making them easy to transport to any location.

Safety features are paramount in the design of the RN30E-CAN and RP30E-CAN. Equipped with automatic shutdown functions in the event of low oil levels and overload protection circuits, they provide peace of mind to users. The generators also boast a weather-resistant casing, ensuring durability and reliability even in adverse conditions.

Finally, both models are designed with noise reduction technology, making them quieter than many traditional generators. This makes them suitable for use in residential areas and during nighttime hours, allowing users to enjoy the benefits of portable power without disturbing their surroundings.

In summary, the Desa RN30E-CAN and RP30E-CAN generators combine power, efficiency, and safety into compact units that meet the needs of diverse users. Their advanced technology, ease of use, and portability make them excellent choices for anyone seeking reliable power on the go.