Desa RP30E-CAN, RN30E-CAN Check GAS Type, Installation Items, Locating Appliance

Page 6

BLUE-FLAME VENT-FREE PROPANE/LP AND

NATURAL GAS GREENHOUSE CO2 GENERATOR

INSTALLATION

NOTICE: The intended use of this appliance is the generation of car- bon dioxide inside greenhouses for plant production.

NOTICE: A qualified service per- son must install appliance. Fol- low all local codes.

where flammable objects are less than 36 inches from the front, top, or sides of the appli- ance

in high traffic areas

in windy or drafty areas

CEILING

Mounting

Bracket

Figure 5 - Mounting Bracket Location

Removing Front Panel Of CO2 Generator

CHECK GAS TYPE

Only use gas type specified on rating plate. If your gas supply is different, do not install appliance. Call dealer where you bought appliance for proper type appliance.

6" Minimum From Sides Of Heater

36" Minimum

1.

Remove two screws near bottom cor-

 

ners of front panel.

2.

Lift straight up on grill guard until it stops.

 

Grill guard will slide up about 1/4".

INSTALLATION ITEMS

Before installing appliance, make sure you have the items listed below.

external regulator (Propane/LP Only, supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

manual shutoff valve *

ground joint union

test gauge connection * (see Figure 13, page 8)

sediment trap

tee joint

pipe wrench

*An A.G.A. or C.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge con- nection. Purchase the optional A.G.A. or C.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 15.

LOCATING APPLIANCE

This appliance is designed to be mounted on a wall.

WARNING: Maintain the mini- mum clearances shown in Figure

4.If you can, provide greater clear- ances from floor, ceiling, and join- ing wall.

WARNING: Never install the CO2 generator

in a home

in a recreational vehicle

Left

Right

Side

Side

 

* Minimum To Floor

FLOOR

*16 3/4"

Figure 4 - Mounting Clearances As Viewed From Front of Appliance

IMPORTANT: Vent-free CO2 generators add carbon dioxide and moisture to the air.

CAUTION:

appliance pilot and burner must be at least 18 inches above floor

locate appliance where mov- ing vehicle will not hit it

For convenience and efficiency, install CO2 generator

where there is easy access for operation, inspection, and service

where strong wind gusts from an open door or ventilator can not blow directly into appliance.

INSTALLING APPLIANCE TO WALL

Mounting Bracket

The mounting bracket is located on back panel of appliance. It has been taped there for shipping. Remove mounting bracket from back panel.

3.

Pull bottom of front panel forward, then

 

down.

4.

Remove cardboard packing from grill

 

and heat shield.

Figure 6 - Removing Front Panel Of CO2 Generator

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Continued

6

105056

Image 6
Contents What to do if YOU Smell GAS Save this manual for future referenceSafety Information If you need assistance or ap- pliance information such asAIR for Combustion and Ventilation Product FeaturesProduct Identification Local CodesAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Appliance to Wall InstallationInstallation Items Check GAS TypeMarking Screw Locations Attaching to Wall Stud MethodConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Gas Supply Piping System Pressure Testing Appliance Gas ConnectionsChecking GAS Connections Operating CO2 Generator For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Technical Service SpecificationsReplacement Parts AccessoriesIllustrated Parts Breakdown RP30E-CAN RN30E-CANODS/PILOT Parts List KEY Part Number Description QTYWarranty Information Limited Warranty Blue Flame VENT-FREE CO2 Generator

RP30E-CAN, RN30E-CAN specifications

Desa RN30E-CAN and RP30E-CAN are cutting-edge compact portable generators that stand out in the market for their versatility and efficiency. Designed for a variety of applications, from camping trips to emergency power supply, these generators provide reliable performance in a compact format.

One of the key features of the RN30E-CAN and RP30E-CAN is their robust engine design. Powered by advanced gasoline engines, both models offer impressive starting capabilities and sustained power output. The RN30E-CAN produces a maximum output of 3,000 watts, while the RP30E-CAN takes it a step further with a peak output of 3,500 watts. This makes them ideal choices for powering essential devices, ranging from small appliances to larger equipment.

Efficiency is another hallmark of these generators. With a focus on fuel economy, both models incorporate innovative technologies that minimize fuel consumption while maximizing power. This not only helps save money but also reduces the environmental footprint of the generators. Users can take advantage of extended run times, making them perfect for longer outings or during unexpected outages.

In terms of user-friendly design, both RN30E-CAN and RP30E-CAN generators come equipped with intuitive control panels that simplify operation. The clear layout allows users to monitor power output and fuel levels effortlessly. Additionally, their lightweight construction, paired with integrated wheels and handles, enhances portability, making them easy to transport to any location.

Safety features are paramount in the design of the RN30E-CAN and RP30E-CAN. Equipped with automatic shutdown functions in the event of low oil levels and overload protection circuits, they provide peace of mind to users. The generators also boast a weather-resistant casing, ensuring durability and reliability even in adverse conditions.

Finally, both models are designed with noise reduction technology, making them quieter than many traditional generators. This makes them suitable for use in residential areas and during nighttime hours, allowing users to enjoy the benefits of portable power without disturbing their surroundings.

In summary, the Desa RN30E-CAN and RP30E-CAN generators combine power, efficiency, and safety into compact units that meet the needs of diverse users. Their advanced technology, ease of use, and portability make them excellent choices for anyone seeking reliable power on the go.