Crown Audio CP660 operation manual Distance

Page 7

CP660 Power Amplifier

3 Setup

3.4 Choose Input Wire

3.5 Choose Output Wire

and Connectors

and Connectors

Crown recommends using pre-built or profes- sionally wired, balanced line (two-conductor plus shield), 22-24 gauge cables with 6 AWG terminal forks, less than 0.31 inch (7.8 mm) wide. Unbalanced line may also be used but may result in noise over long cable runs.

Refer to Figure 3.3 for correct connector pin assignments.

NOTE: Custom wiring should only be performed by qualified personnel.

Crown recommends using pre-built or pro- fessionally wired, high-quality, two- or four- conductor, heavy gauge speaker wire and connectors. You may use banana plugs, spade lugs or bare wire for your output connectors (see Figure 3.4). To prevent the possibility

of short-circuits, wrap or otherwise insulate exposed loudspeaker cable connectors.

Using the guidelines below, select the appro- priate size of wire based on the distance from amplifi er to speaker.

Distance

Wire Size

up to 25 ft.

16 gauge

26-40 ft.

14 gauge

41-60 ft.

12 gauge

61-100 ft.

10 gauge

101-150 ft.

8 gauge

151-250 ft.

6 gauge

CAUTION: Never use shielded cable for output wiring.

Figure 3.3 Input Connector Wiring

Figure 3.4 Output Connector Wiring

Operation Manual

page 7

Image 7
Contents Some models may be exported under the name Amcron CP660Magnetic Field Important Safety InstructionsFamily Name CP Family Model Names CP660 EMC Standards Safety StandardCrown International, Inc European Representative’s Name and AddressTable of Contents Channels into 4-ohm loads How to Use This ManualFeatures WelcomeUnpack Your Amplifier SetupYou may also stack amps without using a cabinet Install Your AmplifierDistance Bridge-Mono Mode Wire Your System 3.6.1 Stereo ModeConnect to AC Mains Setup OperationStartup Procedure Turn up the level of your audio source to an optimum levelPower Indicator Temp IndicatorClip Indicators Power SwitchRotary level controls, one per channel Dual/Mono SwitchPower Cord Level ControlsThis is normal operation for your amp TroubleshootingSpecifications Ventilation Dimensions WidthGeneral Turn OnService Year WarrantyWorldwide Except USA & Canada This page intentionally left blank Model Crown Factory Service Information