Crown Audio CP660 operation manual Specifications

Page 13

CP660 Power Amplifier

6 Specifications

Minimum Guaranteed Power (watts), 120 VAC, 60 Hz

Dual Mode, 1 channel / 1 load

 

1 kHz with <0.3% THD

 

 

 

4 ohm (per ch.)

130

 

 

8 ohm (per ch.)

90

 

 

Dual Mode, 4 channels / 4 loads

 

 

 

1 kHz with 0.3% THD

 

 

 

4 ohm (per ch.)

100

 

 

8 ohm (per ch.)

70

 

 

Dual Mode, 6 channels / 6 loads

 

 

 

1 kHz with 0.3% THD

 

 

 

4 ohm (per ch.)

75

 

 

8 ohm (per ch.)

60

 

 

Bridge-Mono Mode, 2 channels / 1 load

 

 

 

1 kHz with 0.3% THD

 

 

 

8 ohm (per ch.)

250

 

 

Bridge-Mono Mode, 4 channels / 2 loads

 

 

 

1 kHz with 0.3% THD

 

 

 

8 ohm (per ch.)

200

 

 

Bridge-Mono Mode, 6 channels / 3 loads

 

 

 

1 kHz with 0.3% THD

 

 

 

8 ohm (per ch.)

150

 

 

 

 

 

 

 

 

 

Performance

 

Sensitivity (volts RMS)

 

 

for full rated power at 8 ohms

0.7

 

Frequency Response (at 1 watt) 20Hz - 20kHz

+0/–1 dB (see Figure 6.1)

 

 

 

 

Phase Response (degrees at 1 watt) 20Hz to 10kHz

±15 (see Figure 6.2)

 

Signal to Noise Ratio

 

 

A-weighted, below 8-ohm rated power

> 100 dB

 

Total Harmonic Distortion (THD)

 

 

at 8-ohm rated power, 1 kHz, True THD

< 0.3%

 

Intermodulation Distortion (IMD)

 

 

60 Hz and 7 kHz at 4:1, from 8-ohm rated output to –35 dB

< 0.25%

 

Damping Factor (8 ohm) 20Hz to 400Hz

> 250

 

 

 

 

DC Output Offset (shorted input)

< ±50 millivolts

 

Input Impedance, nominal

 

 

balanced, unbalanced

20 k ohms, 10 k ohms

 

Load Impedance (rated)

 

 

Note: Safe with all types of loads.

 

 

Stereo

4-8 ohms

 

Bridge-Mono

8 ohms

Operation Manual

page 13

Image 13
Contents Some models may be exported under the name Amcron CP660Magnetic Field Important Safety InstructionsCrown International, Inc Safety StandardEuropean Representative’s Name and Address Family Name CP Family Model Names CP660 EMC StandardsTable of Contents Features How to Use This ManualWelcome Channels into 4-ohm loadsYou may also stack amps without using a cabinet SetupInstall Your Amplifier Unpack Your AmplifierDistance Bridge-Mono Mode Wire Your System 3.6.1 Stereo ModeStartup Procedure Setup OperationTurn up the level of your audio source to an optimum level Connect to AC MainsClip Indicators Temp IndicatorPower Switch Power IndicatorPower Cord Dual/Mono SwitchLevel Controls Rotary level controls, one per channelThis is normal operation for your amp TroubleshootingSpecifications General Dimensions WidthTurn On VentilationService Year WarrantyWorldwide Except USA & Canada This page intentionally left blank Model Crown Factory Service Information