Updating the iDRAC6 Firmware

Use one of the following methods to update your iDRAC6 firmware.

Web-based Interface (see "Updating the iDRAC6 Firmware Using the Web-Based Interface" on page 40)

RACADM CLI (see "Updating the iDRAC6 Firmware Using RACADM" on page 40)

Dell Update Packages (see "Updating the iDRAC6 Firmware Using Dell Update Packages for Supported Windows and Linux Operating Systems" on page 40)

Before You Begin

Before you update your iDRAC6 firmware using local RACADM or the Dell Update Packages, perform the following procedures. Otherwise, the firmware update operation may fail.

1Install and enable the appropriate IPMI and managed node drivers.

2If your system is running a Windows operating system, enable and start the Windows Management Instrumentation (WMI) service.

3If you are using iDRAC6 Enterprise and your system is running SUSE Linux Enterprise Server (version 10) for Intel EM64T, start the Raw service.

4Disconnect and unmount Virtual Media.

NOTE: If iDRAC6 firmware update is interrupted for any reason, a wait of up to 30 minutes may be required before a firmware update will be allowed again.

5Ensure that the USB is enabled.

Downloading the iDRAC6 Firmware

To update your iDRAC6 firmware, download the latest firmware from the Dell Support website located at support.dell.com and save the file to your local system.

The following software components are included with your iDRAC6 firmware package:

Compiled iDRAC6 firmware code and data

Web-based interface, JPEG, and other user interface data files

Default configuration files

Basic Installation of the iDRAC6

39

Page 39
Image 39
Dell IDRAC6 manual Updating the iDRAC6 Firmware, Before You Begin, Downloading the iDRAC6 Firmware